4016 Series Operation Manual 15 

 

 

  External Input Scale rate adjustment 

  Press the up or down keys to Ext Input scale, press the select key to enter the edit.

 

 

  Press the up, down, left, right keys to edit the data, press the select key to save the 

data, scale range from 1 to 10000. 

 

 

  Press the up or down keys to THD Mode,press the left or right keys to set 

THDR/THDF 

 

 

3.3.3.  General measurement mode 

  General measurement mode 

  Press the number key 1 to enter Meter: 

 

 
 
 

Summary of Contents for 4016 Series

Page 1: ...4016 Series Operation manual S N 900401602 REV E...

Page 2: ...the hazardous substance in all homogeneous materials in the parts is below the relevant threshold of the SJ T 113632006 standard SJ T 11363 2006 Indicates that the concentration of the hazardous subs...

Page 3: ...ck hazard that could result in personal injury FUSES Only fuses with the required rated current voltage and specified type normal blow time delay etc should be used Do not use repaired Fuses or short...

Page 4: ...Safety standard Safety standards following IEC 61010 1 2010 EMC standard EN 61326 1 2006 EN 61326 2 1 2006 EN 55011 2009 A1 2010 EN 61000 3 2 2006 A1 2009 A2 2009 EN 61000 3 3 2008 EN 61000 4 2 2009...

Page 5: ...before using the meter Caution risk of electric shock CAT IV Is for measurements performed at the source of the low voltage installation CAT III Is for measurements performed in the building installa...

Page 6: ...2 11 GPIB INTERFACE OPTION 8 2 12 USB INTERFACE OPTION 8 Chapter 3 Operation 9 3 1 4016 SERIES DIMENSION DESCRIPTION 9 3 2 4016 I O INTERFACE FUNCTION 10 3 3 OPERATING INSTRUCTIONS 11 3 4 EXTERNAL CUR...

Page 7: ...g 3 4 AC Standby power wiring diagram 25 Fig 3 5 DC power accumulation wiring diagram 29 Fig 3 6 Series resistance partial pressure wiring diagram 40 Fig 3 7 CT measurement current wiring diagram 40 F...

Page 8: ...Tables Table 1 1 4016 Series Specifications 2 Table 1 1A 4016 Series Specification 4 Table 4 1 Communication Interface programming setting command summary 48 Table 4 2 GPIB COMMAND TERMINATOR 57...

Page 9: ......

Page 10: ...rrent range 1 2 4 Up to 800Vpeak 200Apeak input 1 2 5 Color graphical display 1 2 6 Data log with Vrms Arms Watt PF VTHD and ITHD 1 2 7 The built in Power switch can be Controlled the ON OFF degree an...

Page 11: ...Table 1 1 4016 Series Specifications AC INPUT LINE 100Vac 230Vac 10 FREQUENCY 50 60 Hz 3Hz PROTECT FUSE 0 5A 250V 5 20mm MAX POWER CONSUMPTION 50VA Model Voltage Current Dimension HxWxD WEIGHT 4016 50...

Page 12: ...mA 0 4Apeak 0 01mA 0 8Apeak 0 1mA Max Input 0 8Apeak 0 5Arms Shunt 5A 0 04 Range 2Apeak 0 1mA 4Apeak 0 1mA 8Apeak 0 001A Max Input 8Apeak 5Arms Shunt 20A 0 005 Range 10Apeak 0 001A 20Apeak 0 001A 40Ap...

Page 13: ...ue Vmax Vmin Amax Amin Wmax Wmin Max Value or Min Value Crest Pactor VCF ICF Peak Value Rms Value Active Power Watt Apparent Power VA Reactive Power VAR Power Factor P F Harmonic Tatal Harmonic Distor...

Page 14: ...check the line voltage is 100V 230Vac 2 2 Check line voltage The 4016 Series AC DC Digital Power Analyzer can operation with 100 Vac 230Vac input as indicated on the label on the rear panel Make sure...

Page 15: ...ector only for 4016 Series mainframe to out of danger when electric leakage And the complete and proper grounded is necessary 2 The 4016 Series high power AC DC Digital Power Analyzer is equipped with...

Page 16: ...F1 F2 Fuse 25A overcurrent protection diodes D1 4 D31 32 and switching components 14016402 are consumables and are not covered by the warranty 2 7 Cleaning 2 8 Power Up The following procedure should...

Page 17: ...connects 4016 Series Digital Power Analyzer to RS232 port of computer in one by one configuration The RS232 BAUD RATE can be set in the front panel Fig 2 3 4016 Series RS232 interface 2 11 GPIB inter...

Page 18: ...pter 3 Operation This chapter describes the front panel function and operation of each 4016 Series Digital Power Analyzer The communication Interface programming is described in Chapter 4 3 1 4016 Ser...

Page 19: ...ut 100 230V 50 60Hz 2 Voltage measurement contact positive terminal 3 Voltage measurement contact negative terminal 4 Positive end of the EUT 5 Negative end of the contact of the EUT 6 Measuring the p...

Page 20: ...016 Power switch 2 Number keys 3 Key 4 Turn output on or off The output switch has an angle control function In the AC mode VSource and VSense need to input power supply to operate normally Key 5 Ente...

Page 21: ...Inrush Current 4 AC Whr Standby Power 5 DC Ahr Whr Accumulator 6 Data Log 7 ON OFF Cycling 3 3 2 Basic system function settings System function setting To set the main menu page press the number key 0...

Page 22: ...Press the up down left right keys to editing data range from 1 to 64 Cycles press the select key to store the data Filter 50 kHz setting Press the up or down keys to filter 50KHZ press the left and r...

Page 23: ...off angle setting Press the up or down keys to Off Degree press the select key to enter the edit Press the up down left right keys to edit press the select key to save the data Electric current measur...

Page 24: ...select key to enter the edit Press the up down left right keys to edit the data press the select key to save the data scale range from 1 to 10000 Press the up or down keys to THD Mode press the left o...

Page 25: ...splay order is Vrms Arms Watt PF VTHD ITHD VA Freq Vpk Vpk Vmax Vmin Apk Apk Amax Amin Wmax Wmin VAR VCF ICF Switch display measurement data and waveform Press the Graph key to switch to display measu...

Page 26: ...4016 Series Operation Manual 17 Meter Mode Setting Press the Edit key to enter the Meter Mode Setting page Press the up or down key to Auto VRange Press the left or right key to set On or Off...

Page 27: ...Press the up or down key to Auto IRange Press the left or right key to set On or Off Press the up or down key to I_Range Press the left or right key to set Current Range Edit display measurement Press...

Page 28: ...isplay item the closed item will automatically move to the end of the page Select the closed display item press the select key to open the display item and lock the indicator the selected item is red...

Page 29: ...e number key 2 under the Menu page mode to enter the harmonic measurement mode Press the On Off key to turn the output on or off Press the up or down key to switch display the harmonic level page Pres...

Page 30: ...peration Manual 21 Harmonic graphic display Press the Graph key to switch data or graphic display When the harmonic graphic is displayed press the up or down key to switch between the V A V and A harm...

Page 31: ...rrent measurement Inrush voltage measurement mode Press the number key 3 under the Menu page mode to enter the inrush voltage and current measurement mode Press the On Off key to turn on the output an...

Page 32: ...or down key to Graph Scroll press the select key to enter the edit graphic shift setting Graph scroll range form 0 100ms Press the up or down key to edit the value press the select key to store the va...

Page 33: ...ent measurement gear setting Press the up or down key to I_Range press the left or right key to switch the set current position Output opening angle setting Press the up or down key to On Degree press...

Page 34: ...e press the select key to enter the closing angle setting Press the up or down key to edit the closing angle press the select key to save the setting angle 3 3 6 AC standby power measurement AC standb...

Page 35: ...rement mode When the output is off press the On Off key to start accumulating power consumption When the output is turned on press the On Off key to stop the accumulated power consumption AC average s...

Page 36: ...dby Power Settings page Press the up or down key to move to the option you want to modify Voltage gear setting Press the up or down key to V_Range press the left or right key to switch the set voltage...

Page 37: ...se to the next gear when the voltage or current exceeds the set gear position Counting function Press the up or down key to Count Mode press the left or right to switch the setting count None Off coun...

Page 38: ...ower cumulative measurement DC power accumulation measurement mode DC power accumulation wiring diagram Fig 3 5 DC power accumulation wiring diagram Press the number key 5 under the Menu page to enter...

Page 39: ...ed on press the On Off key to stop the accumulated power consumption DC average current power graph Press the Graph key to switch to the average current power graphic display page DC current power acc...

Page 40: ...urrent gear setting Press the up or down key to I_Range press the left or right key to switch the set current position Automatic upshift setting Press the up or down key to Range_AutoUp press the left...

Page 41: ...Down Time countdown Press the up down key to xxHr xxMin xxSec press the select key to enter the counting time setting Press the up down left right key to edit the value press the select key to save th...

Page 42: ...data record setting Press the Edit key to enter the measurement data record setting Measurement data record setting Press the up or down key to switch to the item you want to modify Voltage gear sett...

Page 43: ...up or down key to Range_AutoUp press the left or right key to turn the function on or off When this function is turned on it will automatically rise to the next gear when the voltage or current excee...

Page 44: ...er key 7 under the Menu page to enter the switch cycle test Press the On Off key to start the test Press the up or down key to change between displaying the immediate value or the Average value Press...

Page 45: ...e last 256 tests Switch cycle test setting Press the Edit key to enter the switch cycle test setup page Press the up or down key to switch to the option you want to set Switch opening angle setting Pr...

Page 46: ...setting Press the up or down key to Off Degree press the select key to enter the setting switch closing angle Press the up down left right keys to modify the value press the select key to save the se...

Page 47: ...setting Press the up or down key to Off Time press the select key to enter the setting switch to turn off the hold time Press the up down left right keys to modify the value press the select key to sa...

Page 48: ...value press the select key to save the set value Voltage gear setting Press the up or down key to V_Range press the left or right key to switch the setting position Current gear setting Press the up o...

Page 49: ...tial pressure measurement current AC Source output AC Load output R VR 2 5Vpea k 4016 Fig 3 6 Series resistance partial pressure wiring diagram 3 4 2 CT measurement current wiring diagram AC Source ou...

Page 50: ...4016 Series Operation Manual 41 3 5 1 Three phase measurement wiring connection diagram R R T T S S N S T N R Fig 3 8 4016 three phase four wire Y connection 3 sets of electricity meter wiring diagram...

Page 51: ...42 PRODIGIT 3 5 2 Three phase three wire connection three groups of meter connection R R T T S S R S Fig 3 9 4016 three phase three wire connected to three sets of electricity meter wiring diagram...

Page 52: ...4016 Series Operation Manual 43 3 5 3 Three phase three wire connection Two groups of meter connection R T S S T R Fig 3 10 4016 three phase three wire connected to two sets of meter diagram...

Page 53: ...4 2 1 Press the EDIT key under the Menu page to enter the Edit GPIB Settings page Press the Select key to enter the edit Number keys or up and down keys to set the value Press the Select key to finish...

Page 54: ...E CONNECTION OF REAR PANEL PIN Abbreviation Description Pin1 CD Carrier Detect Pin2 RXD Receive Pin3 TXD Transmit Pin4 DTR Data Terminal Ready Pin5 GND Ground Pin6 DSR Data Set Ready Pin7 RTS Request...

Page 55: ...THDF NL MEAS ITHDR NL MEAS ITHDF NL MEAS KWH NL uWhr mWh Whr kWhr MEAS AVGWATT NL uW mW W kW MEAS ELT NL D H S MEAS INRUSHV NL V MEAS INRUSHI NL mA A MEAS GROUP NL V V V V V uA mA A uA mA A uA mA A uA...

Page 56: ...0V 5 400V 6 800V IRANG NL 1 18 1 2mA 2 4mA 3 8mA 4 20mA 5 40mA 6 80mA 7 0 2A 8 0 4A 9 0 8A 10 2A 11 4A 12 8A 13 10A 14 20A 15 40A 16 50A 17 100A 18 200A SHUNT NL INT EXT FILTER NL ON OFF ONDEG NL 0 35...

Page 57: ...NL Set Off Degree GRAPHT SP 0 100 00 NL Set_Inrush Graph T REMote NL Set Remote LOCAL NL Set Local CLEAR NL Clear MaxMin Data ONTIME SP 0 200 600 000 NL Set Output OnTime OFFTIME SP 0 200 600 000 NL S...

Page 58: ...ion 4 6 1 PRESET Set and Read the Default of Load VRMS Syntax MEAS VRMS NL Description Read Voltage rms VPEAK Syntax MEAS VPEAK NL Description Read Voltage VPEAK VMAX MIN Syntax MEAS VMAXMIN NL Descri...

Page 59: ...tion Read measurement frequency VH Syntax MEAS VH NL Description Reading the measured voltage 50th harmonic IH Syntax MEAS IH NL Description Reading the measured current 50th harmonic VTHDR Syntax MEA...

Page 60: ...ease refer to 1 6 Specifications the watt decimal place is composed of voltage and current gear Decide Volt Graph VRange 400V 0x00 0x2A 0xF8 110 00V Current Graph IRange 10A 0x80 0x1F 0x40 8 000A Watt...

Page 61: ...reading you need to send command LOCK OFF to unlock the data The starting point of the graphic data is random not starting from 0 degrees W GRAPH For RS232 or USB Interface only Syntax MEAS WGRAPH NL...

Page 62: ...Syntax IRANG NL Description Current range Return 1 2mA 2 4mA 3 8mA 4 20mA 5 40mA 6 80mA 7 0 2A 8 0 4A 9 0 8A 10 2A 11 4A 12 8A 13 10A 14 20A 15 40A 16 50A 17 100A 18 200A SHUNT Syntax SHUNT NL Descrip...

Page 63: ...Syntax OFFTIME NL Description Ask the switch to the off hold time setting Return Sec REPEAT Syntax REPEAT NL Description Ask the switch to repeat the test number setting Return SCALE Syntax SCALE NL...

Page 64: ...ng 1 20V 2 40V 3 80V 4 200V 5 400V 6 800V IRANG Syntax IRANG SP 0 18 NL Description Set the Current position Return 0 Automatic shifting 1 2mA 2 4mA 3 8mA 4 20mA 5 40mA 6 80mA 7 0 2A 8 0 4A 9 0 8A 10...

Page 65: ...hold time Cycling Mode OFFTIME Syntax OFFTIME SP 0 200 600 000 NL Description Set switch off hold time Cycling Mode REPEAT Syntax REPEAT SP 1 9999 NL Description Set the number of switch cycle tests C...

Page 66: ...description The contents of the symbol must be used as a part or data of the GPIB command it cannot be omitted The contents of the symbol indicts the command can be used or not It depends on the test...

Page 67: ...58 PRODIGIT Appendix 1 4016 series USB Instruction 1 Install the USB DRIVER select USB SETUP PL 2303 Driver Installer exe...

Page 68: ...ion Manual 59 2 After the installation connect the 4016 series and PC with USB Then select the item USB to Serial Port COM3 set the BAUD RATE and Flow control to 115200bps and Hardware to control 4016...

Page 69: ...appear first Please select the public network and press Access The following screen appears If no device appears press F5 to re detect or check if the first step is completed normally 3 The currently...

Page 70: ...et port of HTTP setup The default is 80 no need to set vii Socket port of serial I O Please set to 4001 viii Socket port of digital I O Please set to 5001 ix Destination IP address socket port TCP cli...

Reviews: