7. Part Numbers and Accessories
7.1. Units
Part No.
Description
326 10 001
Pundit Lab consisting of: Display unit, 2 transducers (54kHz), 2 BNC
cables 1.5 m, couplant, calibration rod, battery charger with USB-cable, 4x
AA(LR6) batteries, data carrier with software, documentation and carrying
case
326 20 001
Pundit Lab
+
consisting of: Display unit, 2 transducers (54kHz), 2 BNC
cables 1.5 m, couplant, calibration rod, battery charger with USB-cable, 4x
AA(LR6) batteries, data carrier with software, documentation and carrying
case
7.2. Transducers
325 40 026
Transducer 24 kHz (Two required for operation)
325 40 131
Transducer 54 kHz (Two required for operation)
325 40 141
Transducer 150 kHz (Two required for operation)
325 40 176
2 Exponential transducer 54 kHz, including calibration rod
325 40 177
Transducer 250 kHz (Two required for operation)
325 40 175
Transducer 500 kHz (Two required for operation)
325 40 049
2 Shear wave transducers 250 kHz, including couplant
7.3. Parts and Accessories
326 80 211
Pundit lab carrying bag
325 40 059
Amplifier for long cables (>10m) and exponential transducer (not required
for Pundit Lab
+
)
325 40 021
Cable with BNC-plug, L=1.5m (5ft)
710 10 004
Cable with 2x BNC-plug, L=3.6m (12ft)
325 40 022
Cable with BNC-plug, L=10m (33ft)
325 40 024
Cable with BNC-plug, L=30m (100ft)
710 10 031
Ultrasonic couplant, 250 mL bottle
325 40 048
Shear wave couplant
710 10 028
Calibration rod 25 µs for Pundit
710 10 029
Calibration rod 100 µs for Pundit
351 90 018
USB cable 1.8m
341 80 112
USB charger, global
326 01 033
Demo Block Pundit Lab
325 40 150
Transducer Holder complete
8. Maintenance and Support
Error Screen
If this screen appears during
measurements,
it indicates that no stable signal has been
received.
If this occurs :
Do the measurement in continuous mode.
Change voltage pulse or gain.
Use the waveform display to determine optimal voltage and gain settings.
1.0
Signal too weak
2.0
Invalid measurement (The condition t1 >t2/2 during crack-measurement is not ful-
filled)
11.0
Memory full
37.0
Pundit Lab
+
only. Invalid system time (Back-up battery for the real time clock is
probably empty)
Support Concept
Proceq is committed to providing a complete support service for this instrument by means of
our global service and support facilities. It is recommended that the user register the product
on www.proceq.com to obtain the latest on available updates and other valuable information.
Standard Warranty and Extended Warranty
The standard warranty covers the electronic portion of the instrument for 24 months and the
mechanical portion of the instrument for 6 months.
An extended warranty for one, two or three years for the electronic portion of the instrument
may be purchased up to 90 days of date of purchase.