8. Part Numbers and Accessories 

8.1 Units 

Part No.

 

Description

790 10 000

Zonotip 

unit consisting of: Indicating device with calibration sample, transducer 4.0 MHz, 

transducer cable 2pol 1.2 m, couplant, battery charger with USB cable, carrying strap, data 
carrier with software, documentation, protective pouch, carrying case

790 20 000

Zonotip

+

 unit consisting of: Indicating device with calibration sample, transducer 4.0 MHz, 

transducer cable 2pol 1.2 m, transducer 2.5 MHz, transducer cable 1pol 1.2 m, couplant, 
battery charger with USB cable, carrying strap, data carrier with software, documentation, 
protective pouch, carring case

8.2 Parts and Accessories

790 11 001

D1771 Ultrasonic Transducer 4.0 MHz

790 12 001

S3567 Ultrasonic Transducer 2.5 MHz

710 10 031

Ultrasound couplant, 250 ml

790 80 001

Step Test Block (inches)

790 80 002

Step Test Block (mm)

9. Maintenance and Support 

9.1 Support Concept 

Proceq is committed to providing a complete support service for this instrument. It is recom-
mended that the user registers the product on the www.proceq.com to obtain valuable information 
on available updates and other useful information.

9.2 Standard Warranty and Extended Warranty 

The standard warranty covers the electronic portion of the instrument for 24 month and the me-
chanical portion of the instrument for 6 month. An extended warranty for one, two or three years for 
the electronic portion of the instrument may be purchased up to 90 days of purchase.

Summary of Contents for 790 10 000

Page 1: ...Made in Switzerland Operating Instructions Thickness Gauge...

Page 2: ...Norm Mode 10 4 1 3 Memory Mode 11 4 1 4 A Scan Mode 12 4 2 Pictograms 13 4 2 1 Signal Strength Indicators and Measurement Method 13 4 2 2 Operation Pictograms A Scan 14 4 3 Setup Screen 14 4 3 1 Creat...

Page 3: ...nd its components Unauthorized structural modifications to the instrument and its components Serious damage resulting from the effects of foreign bodies accidents vandalism and force majeure All infor...

Page 4: ...probe is installed has cavities the US pulses will be reflected from them and the thickness is determined as the shortest distance from the external surface to these cavities The Zonolink Software in...

Page 5: ...Navigation keys Zeroing sample test plate USB Port Figure 2 The Zonotip instrument Figure 3 Connection of the 4 0 MHz transducer Make sure the red cable is connected to the port with the red dot Figu...

Page 6: ...as or in areas that are harder to access The 2 5 MHz is included when purchasing the Zonotip unit It is also available separately Figure 5 4 0 MHz transducer D1771 Figure 6 2 5 MHz transducer S3567 3...

Page 7: ...The different modes are explained in chapter 4 1 Select the probe which you have connected A text will appear on the screen Please follow these instructions This process is needed to calibrate the in...

Page 8: ...aterial 3 Calibrating on 4 Monitor 5 Limit beginning 6 Limit end 7 Discrete 8 Sound 9 Vibration 10 Language 11 Measuring units 12 Brightness 13 Mode 1 Probe 2 Material 3 Calibrating on 4 Monitor 5 Lim...

Page 9: ...4 Run for details see 4 3 2 Edit Monitor 5 Inside Off Outside Limit beginning 6 Edit for details see 4 3 2 Limit end 7 Edit for details see 4 3 2 Discrete 8 0 1 Select the number of decimals 0 01 Sou...

Page 10: ...bles the Zonotip to promptly determine the thickness of the test object and to set the monitor 5 response range If monitor 5 is set to inside and the readings are within the defined limits the reading...

Page 11: ...ill appear on the instrument screen To store a measurement please press 1 Active bookmark of the Memory mode 2 Battery charge indicator 3 Measurement units 4 Measurement result 5 Indicator of the meas...

Page 12: ...ntal bar can be adjusted The gate feature is especially useful for situations where several echos appear in the A Scan Therefore the gate must be moved to the echo that needs to be evaluated The scree...

Page 13: ...Horizontal scrolling of the signal on the screen Set the signal gain in decibel 4 2 Pictograms 4 2 1 Signal Strength Indicators and Measurement Method Norm Mode and Memory Mode only Signal level is m...

Page 14: ...of the signal within the gate is used for the measurement Selection of the measurement method Auto Correlation Function ACF is applied to the signals within the gate 4 3 Setup Screen 4 3 1 Create a Ne...

Page 15: ...t response conditions for color sound or vibration alarm Inside results are within the set interval Outside results are not in the set interval Off monitor is switched off Limit beginning 6 All Modes...

Page 16: ...rganic glass 2550 Marble 6150 Tantalum 4235 Silicate glass 5500 Silver 3600 Manganese 5561 Teflon 1350 Lead 2160 Magnesium 5790 Steel St3 5930 Tin 3320 Cast iron 3500 5600 Textolite 2920 Nickel 5630 L...

Page 17: ...r the user can select any folder to save the data in The default name of the file will have the format resultsX where X is an index number The index number is generated automatically from the numbers...

Page 18: ...250 g Display type TFT Permissible surface roughness Rz160 N12 Ra 50 m Minimum curvature radius 10 mm 0 4 inch Ultrasonic velocity range from 1000 to 9999 m s Data memory 100 groups each max 500 measu...

Page 19: ...ase 8 2 Parts and Accessories 790 11 001 D1771 Ultrasonic Transducer 4 0 MHz 790 12 001 S3567 Ultrasonic Transducer 2 5 MHz 710 10 031 Ultrasound couplant 250 ml 790 80 001 Step Test Block inches 790...

Page 20: ...oceq com Proceq Rus LLC Ul Optikov 4 korp 2 lit A Office 410 197374 St Petersburg Russia Phone Fax 7 812 448 35 00 info russia proceq com Proceq Middle East P O Box 8365 SAIF Zone Sharjah U A E Phone...

Reviews: