Procentec Atlas 101-800110 User Manual Download Page 7

 
© PROCENTEC 

7/58 

 

1.

 

Product description 

1.1

 

Introduction 

PROCENTEC’s Atlas is the solution for monitoring and diagnosing Ethernet networks, where innovative 
simplicity and predictive capabilities are desired. The tool is perfect for preventing unexpected and expensive 
downtime within industrial Ethernet networks.  
PROCENTEC’s Atlas provides unique insight in your networks health and topology. With PROCENTEC Atlas 
operators and engineers can easily detect problems and find their causes within your network. This prevents 
costly down times.  
 
The ease of use and clear overview makes this an ideal solution for the complete understanding of networks, 
always and anywhere. Atlas is a compact device, that can be installed on a DIN rail and plugged in to the 
network. Atlas does not require additional and time-consuming software installations on the PC. You can get all 
the information using a custom designed web application. All the information Atlas gives, can be viewed on the 
central, customizable dashboard page. 

1.2

 

Your benefits 

 

Ease of use 

 

Use of Industrial Ethernet 

 

Topology 

 

Standalone device, 24/7 available 

 

Safe use 

 

Customizable dashboard 

 

Resistant to all environmental factors 

 

Easy to install via DIN rail 

 

No software required 

1.3

 

Product features 

 

Network Topology 

 

Customizable dashboard 

 

Network Quality Factor 

 

Alarms 

 

Not vendor or protocol specific 

1.4

 

System requirements 

Atlas runs on any browser-enabled computer; the interface is fully web based. 
HTML5 and JavaScript must be supported by the browser. 
 
The minimum version requirements for web browsers are: 

 

Chrome 

 

version 46 or higher 

 

Edge   

 

version 25 or higher 

 

Firefox   

 

version 42 or higher 

 

Internet Explorer 

version 11 or higher 

 

Safari    

 

version 5 or higher 

 

 

Summary of Contents for Atlas 101-800110

Page 1: ...Atlas User Manual...

Page 2: ...r may be required to take adequate measures Warranty Warranty is void if you open Atlas Qualified Technicians Only qualified technicians should be allowed to install and work with this equipment Quali...

Page 3: ...de if mistreated Do not disassemble or dispose of in fire Dispose product according to the instructions For further information about environment friendly recycling and the procedure for the disposing...

Page 4: ...ne of its official names 13 5 2 Installing the PROCENTEC root certificate 14 5 2 1 For Chrome 14 5 2 2 For Internet Explorer 14 6 Dashboard 15 6 1 System buttons 15 6 2 Dashboard organization 17 6 3 C...

Page 5: ...9 17 1 General tab 39 17 2 User tab 39 17 3 Date time 40 17 4 Ethernet office Ethernet factory 40 17 5 Network monitoring 41 17 6 Email 41 17 7 System 42 17 8 Updates 42 17 9 About 43 18 License manag...

Page 6: ...PROCENTEC 6 58 27 Notes 57...

Page 7: ...ork Atlas does not require additional and time consuming software installations on the PC You can get all the information using a custom designed web application All the information Atlas gives can be...

Page 8: ...255 255 255 0 STEP 5 Open a web browser and go to https 192 168 1 10 You will receive a 5 2 warning about the certificate Chrome users should click ADVANCED followed by Proceed Internet Explorer Edge...

Page 9: ...e installed on a horizontal 35mm DIN rail with the front plates facing forward see Figure 1 for an example In this position the generated heat of the module can escape through the grid in the top of t...

Page 10: ...twork Pointers about the IP address configuration In case your office and factory share the same sub network you should NOT connect and configure the Office port Just make sure that the default Office...

Page 11: ...the Atlas the default address is 192 168 1 10 for the office side and 192 168 0 10 for the factory side 4 1 Terminology and definitions In this manual the following terms and definitions are used to r...

Page 12: ...PROCENTEC 12 58 Table Options Location Icon Column Options Figure 5 Terminology used in the web interface continued...

Page 13: ...the Atlas it claims to be Therefor every Atlas has a unique SSL certificate containing four valid ways to contact your Atlas https 192 168 0 10 the default factory IP address https 192 168 1 10 the d...

Page 14: ...Browse Select Trusted Root Certification Authorities and press OK Click Next followed by Finish You will receive a security warning Click Yes followed by OK Now restart Chrome You can now connect to y...

Page 15: ...ve extra information or functionality Measurement Button When clicking the spinning measurement button a dropdown menu will show This dropdown shows how long the measurement is running The Change meas...

Page 16: ...ations aren t removed and are therefore still available for CSV export By clicking Export All CSV you can download a full history of all the notifications regardless of any previous clearings of the l...

Page 17: ...will appear marked with a sign By clicking on the sign a popup window will appear Select the tile you would like to place by clicking on it The popup will close and the tile will be placed During edit...

Page 18: ...ertain user or group of users has The default password for an account is the same as the username So the password for the admin account is admin All letters are lowercase also for the username The def...

Page 19: ...t Yes Yes No Clear the Notifications Yes Yes No Clear the Measurement Data Yes Yes No Customize the Dashboard add remove tiles Yes Yes No View use the Trending page Yes Yes No View use the OPC UA page...

Page 20: ...lways use strong passwords Avoid test 123456 your company name your first name Atlas PROCENTEC etc Change passwords immediately if they may have been compromised If passwords must be written down stor...

Page 21: ...that the Atlas will be connected to This name will be used in the web interface and reports You can also enter optional contact details for colleagues in need of assistance Step 3 Then choose an Offi...

Page 22: ...pply topology information These are connected either to a question mark icon or are placed as stand alone devices The devices linked to a question mark icon and then in turn to other devices means the...

Page 23: ...ee view will be re organized with the selected device at the top 9 1 3 Custom view From within the galaxy view it is possible to create custom views After a custom view is given a name there will appe...

Page 24: ...find the Graph Search functionality First click on the magnifier icon This will trigger an input field to be shown Here you can enter the name IP address or MAC address of the desired device Autocompl...

Page 25: ...the necessary data to do so cannot be obtained There are multiple explanations for this problem 1 It is an unmanaged switch This is a standard switch that does not supply data to determine the topolog...

Page 26: ...red There is another device on the network with the same IP address This could make both devices unusable You are advised to resolve this issue immediately by changing the IP address of one of the dev...

Page 27: ...shown for the device For more information on the various items please check the description of the overview section ComBricks In case the device is a ComBricks Head Station it will show a table with...

Page 28: ...usual the red cross which indicates that the device is lost will be faded Double IP addresses are ignored Firmware difference are ignored Link errors and warnings will not be shown if you ignore devic...

Page 29: ...Depending on the type of device information is shown in groups Linked devices Device name MAC address and port number are shown for both sides of the connection Load For each direction the last and ma...

Page 30: ...rs There are multiple Q Factors in use in the tool A Q Factor for each network device which indicates the quality for a single network device Calculation of this Q Factor is based on a weight of o Net...

Page 31: ...twork user attention required Yellow light a situation is present which is important but not serious user attention recommended Green light all seems to be working correctly no important or critical s...

Page 32: ...ending descending or none Columns can be resized by placing the mouse between columns and then selecting dragging the splitter Columns can be hidden by selecting the icon on the far right of the table...

Page 33: ...oad in for the incoming ingress port If a network device has more than one port the highest load is shown See warning below Min incoming load The lowest measured network load in for the incoming ingre...

Page 34: ...al network protocols the software version can be retrieved e g for PROFINET This can help to verify that the product has the latest or stable software version Hardware version For certain industrial n...

Page 35: ...ices report an incorrect link speed e g 10 Mbps instead of 100 Mbps Since the link speed is used to calculate the load the reported load can be incorrect If the reported load is very high check the li...

Page 36: ...ible The steeper the trend becomes the quicker you are required to act The trend also provides insight into what has happened in the past This could provide clues on where to look at and what to do ne...

Page 37: ...tlas General information Atlas information Q Factor Device List Ignored Devices Traffic Light Firmware Differences Before generating the Report you need to fill in some mandatory details marked in red...

Page 38: ...client to Atlas and the ability to start the server Once the OPC UA server is started the button will change into Stop server This means the OPC UA server is active When a connection has been establi...

Page 39: ...interface language of the Atlas The Network name Network location Technical contact name and Technical contact phone all show up in the Report The Network name also shows up on the dashboard of Atlas...

Page 40: ...erver s then you can remove and replace these defaults servers In case you do not want to use automatic time you can turn it off and manually set the time 17 4 Ethernet office Ethernet factory Both th...

Page 41: ...ing properties of your network and or devices Traffic light Devices which are slow to respond Devices which are lost Devices with InErrors Devices with InDiscards Devices which have lost ping packets...

Page 42: ...e the USB ports for security reasons or company policy compliance 17 8 Updates New firmware can be downloaded from the PROCENTEC website and uploaded in the Updates tab More instructions about updatin...

Page 43: ...cense manager to see which features are enabled or to upload a new license The license manager can be reached via the Atlas licenses button within the about tab on the settings page Another way of ope...

Page 44: ...firmware is detailed in the following steps Step Instructions STEP 1 Download the latest firmware for Atlas from the PROCENTEC website STEP 2 Login into the Atlas open Settings and navigate to the Up...

Page 45: ...approximately 2 minutes After the reset it will reboot and be reachable on the default IP addresses again You need to fill out the Setup Wizard before the Atlas can continue normal operation again Unt...

Page 46: ...DP SNMP To report status information to external devices To collect topology data from the devices on the factory network 443 TCP HTTPS Used for the web interface 4840 TCP OPC UA Only used when the OP...

Page 47: ...DIN 40 050 Power supply Pluggable power supply connector Nominal power supply voltage Absolute maximum rated voltage Nominal power use Maximum power use Current consumption 12VDC Reverse polarity pro...

Page 48: ...9C B2 06 2D 3F FF OPC UA PROFINET detect only PROFINET I M0 Modbus TCP detect only Ethernet IP detect only ARP ICMP DCP SNMP PROFINET I M0 Factory 192 168 0 10 Office 192 168 1 10 admin admin Up to 2...

Page 49: ...PROCENTEC 49 58 23 Order codes Component Order code Remarks Atlas 101 800110 Atlas main unit including mounting materials...

Page 50: ...PROCENTEC 50 58 24 Certificates...

Page 51: ...2164 W www PROFIBUScentre com au BELGIUM and LUXEMBOURG Bintz Technics N V T 32 2 720 49 16 Brixtonlaan 23 F 32 2 720 37 50 B 1930 Zaventem E bloemen bintz be Belgium W www bintz be BRAZIL Westcon Ins...

Page 52: ...21 831 663 29 D 76185 Karlsruhe E info procentec de Germany W www procentec de INDIA UL Engineering Services Software Pvt Ltd T 91 202 696 0050 Nirman Classic F 91 202 696 2079 Katraj Kondhwa Road E d...

Page 53: ...ec com Netherlands W www procentec com NORWAY Nortelco Automation AS T 47 22 57 61 00 Johan Scharffenbergs vei 95 E post nortelcoautomation no N 0694 Oslo I www nortelcoautomation no Norway PERU Contr...

Page 54: ...zzentrum F 41 0 34 426 68 13 Jlcoweg 1 E max felser bfh ch CH 3400 Burgdorf W www profitrace ch Switzerland TAIWAN Full Data Technology T 886 2 8751 99 41 90 97 6F No 200 Gangqian Rd F 886 2 8751 95 3...

Page 55: ...45 1630 W Diehl Road F 1 630 245 17 17 Naperville Illinois 60563 E sales gridconnect com USA W www gridconnect com procentec html VIETNAM Bavitech Corporation T 84 8 3547 09 76 42 Truong Son Street F...

Page 56: ...support engineers who provide technical support on site and online Our professionals have more than 20 years of experience with PROFIBUS and PROFINET technology They provide the necessary support to e...

Page 57: ...PROCENTEC 57 58 27 Notes...

Page 58: ...PROCENTEC BV Klopperman 16 2292 JD Wateringen The Netherlands T 31 0 174 671 800 F 31 0 174 671 801 E support procentec com W www procentec com...

Reviews: