Operation
17 / 43
51500024
V2
GB
4
Operation
4.1
Charging the Lithium Ion Batteries
Before the daily use of the machine, it is recommended to charge the lithium-ion batteries completely!
The lithium-ion batteries may only be recharged by suitably qualified persons.
Due to electrical voltage (230 v /400V) there is a danger to life if used improperly.
•
Check the battery charging capacity in the display (in the driver's cab)
→
see the following chapter "Operation" or
"Display - Function overview".
•
Open cover (see following chapter "Opening the cover")
There are two ways to charge the two lithium-ion batteries:
-
with 230 V
→
Charging time approx. 4.6 h (from 0 to 100% charging capacity)
-
with 440 V
→
Charging time approx. 2.3 h (from 0 to 100% charging capacity)
After the start, the digital instrument displays the string of the following
parameters:
•
BATTERY VOLTAGE
(two-colour red upper LED).
•
Current
supplied by the charger (two-colour red lower LED).
•
TIME
in hours missing until the end of charging (two-colour green
upper LED).
•
Ah
(two-colour green lower LED).
By pressing the MODE key, the sequence of the parameters is locked and
the last displayed value is retained. Press the MODE button again to
restart the parameter sequence.
Charging socket for
charging cable for 400V
Charge and for charging
cable with adapter plug
for 230V charge
Summary of Contents for VM-301-KJ-GREENLINE
Page 16: ...General 15 43 51500024 V2 GB 3 2 Survey and construction...
Page 41: ...Maintenance and care 40 43 51500024 V2 GB 7 2 Lubrication plan...
Page 42: ...Maintenance and care 41 43 51500024 V2 GB...
Page 45: ......
Page 47: ......
Page 69: ......