8
5.2
CAN-MATRIX
For detailed information see attached CAN parameter list. Optional CAN configurations are
listed below
▪
CAN protocol CAN
2.0 A
▪
Baud rate of the CAN interface250k
▪
120 Ohm termination resistor integrated in termination
For smooth CAN communication, another 120 Ω
Terminating resistor required. Star taps should be avoided.
5.3
PIN ASSIGNMENT
DANGER
▪
Separation of power under load must be avoided to protect persons and components.
When changing the power cabling or pulling a plug, make sure that the system is
switched off.
WARNING
▪
The power must always be connected before communication.
▪
The communication plug must be disconnected before the power connection
▪
If changes are made to the power cabling, the system must be switched off.
5.3.1
Power connector
Designation
Manufactu
rer
Battery page
Opposite side
Peculiarity
Connector
APP
940-BK, SB175A, grey
940-BK, SB175A, grey
Service contact
APP
1383-BK, PP180, AWG2
1383-BK, PP180, AWG2
Waterproof rubber
protection cap
APP
3-6036P1, Boot, Cover
Source
3-6037P1, boat, cover load
Table 5: Power connectors and accessories
5.3.2
Communication plug
Designation
Manufactu
rer
Connector Battery side Connector opposite side
Drive
communication connector
Delphi
15326660 - f
15326661 - m
Communication connector
termination/parallel operation
Delphi
15326661 - m
15326660 - f
Communication connector
Battery
Bulgin
PX0413/12S/PC
PX0410/12P
Table 6: List of communication plugs
The power and communication plugs for the vehicle side are not included in the scope of
delivery. For additionally required contacts, the following table lists the manufacturer numbers
for the contacts.
Summary of Contents for VM-301-KJ-GREENLINE
Page 16: ...General 15 43 51500024 V2 GB 3 2 Survey and construction...
Page 41: ...Maintenance and care 40 43 51500024 V2 GB 7 2 Lubrication plan...
Page 42: ...Maintenance and care 41 43 51500024 V2 GB...
Page 45: ......
Page 47: ......
Page 69: ......