Installation Using Flush Mount Ring Bracket (Option)
Installation -
2
Drilling the Hole on
the Ceiling
Fix the Main Body
Connect Wire the
Cables and
Terminal Blocks
4
Fix the Flush Mount
Ring Bracket to the
Main Body
3
Separate the
Lock-up Screws
from the Main Body
2
2
3
4
5
1
2
1
5
3
4
6
Drilling the Hole on the Ceiling
To pass cables through the ceiling, drill a hole(70mm
diameter) on the ceiling.
Separate the Lock-up Screws from the Main Body
Separate the 4 lock-up screws from the main body in
advance.
Fix the Flush Mount Ring Bracket to the Main Body
Fix the flush mount ring bracket to the main body
using torx screws.
Connect Wire the Cables, Terminal Blocks
- Connect the terminal blocks to the main body.
- Refer the previous page for detailed information.
Fix the Main Body
Screw the main body with the surface mount bracket
to the ceiling using the screws on the surface mount
bracket.
Detach the Protection Film
Detach the protection film from the dome cover.