Probe PMA-H2000 User Manual Download Page 20

FUNCTION SETUP > GROUP SETUP

OSD -

1

2

<

FUNCTION SETUP

>

====================================================

<

PRESET SETUP

>

<

SCAN SETUP

>

<

PATTERN SETUP

>

<

GROUP SETUP

>

BACK

EXIT

<

GROUP SETUP

>

====================================================

GROUP NUMBER

<

EDIT GROUP 

>

CLEAR GROUP 

BACK

EXIT

1

CANCEL

3

Select ‘<GROUP SETUP>’
and press the ‘NEAR’ key

After define the ‘GROUP NUMBER’, 
select ‘<EDIT GROUP>’
and press the ‘NEAR’ key

GROUP SETUP SCREEN

The group function allows running sequence of presets, pattern
and/or scans. Max. 8 group can be stored. Each group can have 
max. 20 action entities which can be preset, pattern or scan.

Preset speed can be set up and the repeat number of pattern
& scan can be set up in group setup. Dwell time between
actions can be set up also.

EDIT GROUP - Initial Screen

Press the ‘NEAR’ key to start group setup.

EDIT GROUP – Select Function Sequence

Note that max. 20 functions are allowed in a group. 
Move cursor up/down and press the ‘NEAR’ key to set up.

EDIT GROUP - Assign Function

Move cursor to the ‘NO.’ to assign the function, click the enter
button to set up. Select the function by 

clicking up/down button

.

GROUP NUMBER

Selects group number to edit.

<EDIT GROUP>

Starts editing group.

CLEAR GROUP

Deletes data in the current group.

1 ~ 8

CANCEL / OK

NO.

Means the sequence of the function in a group.
The functions will be run from lower no. to higher no. by sequence.

ACTION NUM

Select the function.

DWELL

Sets dwell time between function by moving joystick up/down. If the
‘OPT’ of pattern/group is set to repeat more than twice, it means the
repeat interval.

OPT

It represents preset speed (1~360) when preset is selected. It should
be the number of repetition (1~255) when pattern or scan is selected
for ‘ACTION’.

1 ~ 20

NONE / PRESET 1~255 / PATTERN 1~4
 / SCAN 1~8

00:03 ~ 04:00 (min:sec)

PRESET: 1~360 / PATTERN & SCAN: 1~255

Preset

1

Preset

120

Pattern5

1 Times

Pattern5

n Times

Dwell Time

Max. 20 Entities

Scan3

1

3

4

5

2

3

4

OPT

<

EDIT GROUP

>

====================================================

NO.

====================================================

  1

  2

  3

  4

  5

====================================================

EDIT

SAVE

CANCEL

OPT

Dwell

ACTION

NONE

NONE

NONE

NONE

NONE

Num

<

EDIT GROUP

>

====================================================

NO.

====================================================

  1

  2

  3

  4

  5

====================================================

EDIT

SAVE

CANCEL

OPT

Dwell

ACTION

NONE

NONE

NONE

NONE

NONE

Num

Press the ‘NEAR’ key to start editing

Select function sequence number
by move joystick up/down.
And press the ‘NEAR’ key.

Summary of Contents for PMA-H2000

Page 1: ...In Outdoor Camera HD SDI PTZ Ver 0 6 2011 04 User sManual...

Page 2: ...jury due to re electric shock or falling objects Do not install the unit in humid dusty or sooty locations Doing so may cause re or electric shock If any unusual smell or smoke come from the unit stop...

Page 3: ...tructions have been adhere to 8 Do not install near any heat sources such as radiators heat registers or other apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of th...

Page 4: ...tact your city office waste disposal service or the shop where you purchased the product This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to par...

Page 5: ...on Using Wall Mount Bracket with Junction Box Option Terminal Block 2 Installation 14 15 16 17 18 19 20 22 23 24 25 Check Points before Operation OSD ROOT MENU SYSTEM INFORMATION OSD MOTION SETUP OSD...

Page 6: ...les in advance Terminal Block Power video communication and alarm input cables are connected through the terminal blocks Torx Wrench It is used to screw unscrew the fixed screws on the main body Rubbe...

Page 7: ...erminal Block Slot Power keyboard controller Alarm input and relay out cables are connected to this terminal block LED Reset Button LED for active yellow light power red light status and Reset button...

Page 8: ...bracket to the ceiling Rubber Gasket Before installing the gasket the hole in the center is to be cut by knife when only necessary When installing gasket the protrusion of the gasket should be matche...

Page 9: ...on the ceiling Separate the Lock up Screws from the Main Body Separate the 4 lock up screws from the main body in advance Fix the Flush Mount Ring Bracket to the Main Body Fix the flush mount ring bra...

Page 10: ...Ceiling To pass cables to upside of ceiling drill a hole 30mm diameter on the ceiling Fix the Ceiling Mount Bracket Pass the cables into the ceiling mount bracket and screw the ceiling mount bracket...

Page 11: ...ole about 30 mm on the wall Fix the Wall Mount Bracket Pass the cables into the wall mount bracket and screw the wall mount bracket to the wall Fix the Surface Mount Bracket Pass the cables through th...

Page 12: ...lose cover to the junction box using the torx driver Fix the Sun Shield Bracket Fix the sun shield bracket to the wall mount bracket Connect Wire the Cables Terminal Blocks Connect the terminal blocks...

Page 13: ...de of terminal block Activation type of alarm in out N O N C Output voltage is high state when sensor is activated Output voltage is high state when sensor is not activated Normal Open N O Normal Clos...

Page 14: ...ter you reboot the camera 5 Since the operation method can be different for each controller available refer to the manual for your controller if camera cannot be controlled properly Check Points befor...

Page 15: ...e for basic system setup SYSTEM INFORMATION FIRMWARE VER Shows the current firmware version HD SDI Shows the current resolution of HD SDI PROTOCOL Shows the current PTZ control protocol BAUD RATE Show...

Page 16: ...ck right to set alarm action ALARM INPUT SETUP Alarm Action Setup 1 Move joystick up down to set the action HOME PRESET SCAN PATTERN GROUP and number 2 Move joystick left right to move the focus to se...

Page 17: ...onfigure 4 special functions with this menu 1 PRESET SETUP 255 presets from the number 1 to 255 can be assigned excluding preset 95 131 134 141 148 151 158 reserved for menu PRESET NUMBER Selects the...

Page 18: ...OS 1 CW direction 2 CCW direction 2nd POS SCAN SETUP Up to 8 scans are available which makes the camera to move slowly between two preset positions When scan function runs the camera moves from the pr...

Page 19: ...T PATTERN Select the Position 1 By using joystick move to the start position with appropriate zoom 2 To start the pattern recording press the NEAR or ENTER key 3 To exit this menu press the FAR key ED...

Page 20: ...to set up Select the function by clicking up down button GROUP NUMBER Selects group number to edit EDIT GROUP Starts editing group CLEAR GROUP Deletes data in the current group 1 8 CANCEL OK NO Means...

Page 21: ...Function Move cursor left right to select items and move cursor up down to change each value EDIT GROUP Select Function Sequence e g If PRESET 1 is not defined at ROOT MENU FUNCTION SETUP PRESET SETU...

Page 22: ...een manual focus mode and auto focus mode Manual focus mode activates in preset operation and auto focus mode activates when jog operation starts MANUAL With manual mode at presets focus data is memor...

Page 23: ...IGHT In this mode you can assign AE value in terms of brightness IRIS LEVEL Works when AE MODE is MANUAL or IRIS mode GAIN LEVEL Works when AE MODE is MANUAL Enhances image brightness automatically in...

Page 24: ...HER SETUP BACK EXIT AUTO OFF OTHER SETUP EXP COMPENSATION APERTURE GAMMA PICTURE EFFECT BACK EXIT 0 6 NORMAL OFF 3 OTHER SETUP select and press the NEAR Key EXP COMPENSATION Default is 0 0dB APERTURE...

Page 25: ...IT 1920x1080i60 CANCEL 2400 3 HD SDI Select the resolution of HD SDI CLEAR ALL DATA Deletes all configuration data such as display camera motion setup and so on BAUD RATE 1280x720p50 1280x720p60 1920x...

Page 26: ...Unit mm 115 165 5 4 57 0 64 157 5 NPT 36 5 83 5 46 NPT Dimension Specifications 4...

Page 27: ...1 Flush Mount Ring Bracket 2 Sun Shield Mount Bracket Unit mm Unit mm 43 23 57 5 307 147 122 162 62 200 212 117 46 83 7 4 117 185 Dimension of Option Brackets Specifications 4...

Page 28: ...3 Wall Mount Bracket 4 Ceiling Mount Bracket Unit mm Unit mm 112 6 112 6 46 83 83 5 276 2 46 188 7 4 M4 83 46 112 6 46 83 5 355 5 112 6 4 7 4 7 141 5 141 5 Dimension of Option Brackets Specifications...