Operating Instructions
6.2 Baud rate setting
6.2.1 Use 3-Bit DIP Switch to select other baud rate.
The 3 Bit switch is binary as well, when pull up its value is “0”; when pull down, its
value is “1”. So it comes with 000, 001, 010...111, total 8 kinds, they match some
baud rate as bellow
000 = 2400 (default)
001 = 4800
010 = 9600
011 = 19200
100 = 28800
101 = 38400
110 = 57600
111 = 115200
Change the baud rate according to your RS232 devices’ baud rate. the DIP setting
order is 321, for example DIP setting 110 the first number
“1” follows the 3rd Bit,
the 3rd number
“0” follows the first Bit, it will be 011 on the DIP switch
0 1 1
6.2.2 Setting the Baud rate via Web Browser
Login TX and RX with their default IP (TX: 192.168.1.11; RX: 192.168.1.12) to
modify the Baud Rate which range from default 2400 to 115200.
※
When you change the Baud rate on both Web browser and 6 Bit DIP
switch, the units will follow the latest one.
※
Please send the data in the same group ID.
13
Operating Instructions
2. Specifications
Performance
Protocol
H.264 encoder over TCP/IP
Support Video format
480i/480p/576i/576p/720p/1080i/1080p@60HZ
Support Audio format
LPCM, Audio sampling rate 48KHZ
Streaming Bit Rate
15Mbps
HDCP
Compliant
IR Frequency
38 -56 KHZ
RS232 Baud rate
Default 2400bps, total 8 kinds optional
IP setting &Group ID setting
Default IP
TX: 192.168.1.11 ; RX: 192.168.1.12
Group ID
Group 00 ~ group 63
Request for Switch/Router
Support IGMP, support DHCP
Connectors on Transmitter
Input
1xHDMI Female port
Output
1x RJ45 output , 1x HDMI local output
RS232
DB9 Female port
IR
IR TX port
Connectors on Receiver
Input
1xRJ45 input
Output
1x HDMI Female port
RS232
DB9 Male port
IR
IR RX port
Environmental & Power Requirements
Operating temperature
-5 to +35
℃
(
+23 to +95
℉)
Operating Humidity Range
5 to 90%RH (No Condensation)
Power supply
DC 5V 2A
Power consumption
Max 3 watt
Physical
Dimension
120.2x78.6x29 mm
Net Weight
TX: 0.28KG : RX:0.28KG
2