43
44
Programming
Programming
Custom Program
Day of
the Week
Events
Time
Setpoint
Temperature
(HEAT)
Setpoint
Temperature
(COOL)
Weekday
Saturday
Sunday
Wake/OCC1
Leave/UNOCC1
Return/OCC2
Sleep/UNOCC2
Wake/OCC1
Leave/UNOCC1
Return/OCC2
Sleep/UNOCC2
Wake/OCC1
LeaveUNOCC1
Return/OCC2
Sleep/UNOCC2
Occupied
Unoccupied
Occupied
Unoccupied
Occupied
Unoccupied
Programming
39
40
Default Programming
Factory Default Program
Day of
the Week
Events
Time
Setpoint
Temperature
(HEAT)
Setpoint
Temperature
(COOL)
Weekday
Saturday
Sunday
Wake/OCC1
Leave/UNOCC1
Return/OCC2
Sleep/UNOCC2
Wake/OCC1
Leave/UNOCC1
Return/OCC2
Sleep/UNOCC2
Wake/OCC1
LeaveUNOCC1
Return/OCC2
Sleep/UNOCC2
6 AM
8 AM
6 PM
10 PM
6 AM
8 AM
6 PM
10 PM
6 AM
8 AM
6 PM
10 PM
70
˚
F (21
˚
C)
62
˚
F (17
˚
C)
70
˚
F (21
˚
C)
62
˚
F (17
˚
C)
70
˚
F (21
˚
C)
62
˚
F (17
˚
C)
70
˚
F (21
˚
C)
62
˚
F (17
˚
C)
70
˚
F (21
˚
C)
62
˚
F (17
˚
C)
70
˚
F (21
˚
C)
62
˚
F (17
˚
C)
75
˚
F (24
˚
C)
83
˚
F (28
˚
C)
75
˚
F (24
˚
C)
78
˚
F (26
˚
C)
75
˚
F (24
˚
C)
83
˚
F (28
˚
C)
75
˚
F (24
˚
C)
78
˚
F (26
˚
C)
75
˚
F (24
˚
C)
83
˚
F (28
˚
C)
75
˚
F (24
˚
C)
78
˚
F (26
˚
C)
Programming
1.
Select
HEAT
or
COOL
with the
SYSTEM
key.
Note:
You have to program heat and cool each separately.
2.
Press the
MENU
button (If menu does not appear first, press
RUN SCHED
).
3.
Press
SET SCHED
.
Note:
Monday is displayed and the
WAKE/OCC1
icon is shown. You are now programming the
WAKE/OCC1
time period for that day.
4.
Time is flashing. Use the or key to make your time
selection for that day’s
WAKE/OCC1
time period.
Note:
If you want the fan to run continuously during this time
period, select
ON
with the
FAN
key. If you want to use
IAQ
mode during this time period, select
IAQ
with the
FAN
key.
5.
Press
NEXT.
6.
The setpoint temperature is flashing. Use the or key
to make your setpoint selection for that day’s
WAKE/OCC1
period.
7.
Press
NEXT.
8.
Repeat steps 4 through 7 for that day’s
LEAVE/UNOCC1
time period, for that day’s
RETURN/OCC2
time period,
and for that day’s
SLEEP/UNOCC2
time period.
To customize your 7 day 4 time period Program schedule, follow
these steps:
Monday:
Repeat steps 4 through 8 for the remaining days of the week.
A Note About Auto Changeover:
In Auto you have the ability to switch between Auto Heat or Auto Cool
by pressing the system key. This can be done once the current mode has
reached its setpoint. For example: if in Auto Heat, the heat setpoint must
be satisfied before the thermostat will allow you to switch to Auto Cool.
You can switch out of Auto by holding down the system key. To get back
into Auto, you must toggle the system key to Auto.
Factory Default Program for 2 Time Periods
Day of
the Week
Events
Time
Setpoint
Temperature
(HEAT)
Setpoint
Temperature
(COOL)
Weekday
Saturday
Sunday
OCCUPIED
UNOCCUPIED
OCCUPIED
UNOCCUPIED
OCCUPIED
UNOCCUPIED
8 AM
6 PM
6 PM
6 PM
8 AM
70
˚
F (21
˚
C)
62
˚
F (17
˚
C)
78
˚
F (26
˚
C)
83
˚
F (28
˚
C)
8 AM
70
˚
F (21
˚
C)
62
˚
F (17
˚
C)
70
˚
F (21
˚
C)
62
˚
F (17
˚
C)
78
˚
F (26
˚
C)
83
˚
F (28
˚
C)
78
˚
F (26
˚
C)
83
˚
F (28
˚
C)
You can use the table on the next page to plan your customized program
schedule if using 5+1+1.
Default Programming