V1.0
6,500W Gasoline Generator with Electric Start
8630741
TROUBLESHOOTING
Contact Princess Auto Ltd. for a solution if the generator does not function properly or parts are
missing. If unable to do so, have a qualified technician service the generator.
PROBLEM(S)
POSSIBLE CAUSE(S)
SUGGESTED SOLUTION(S)
Engine will not
start.
1. Engine is cold.
2. Fuel valve in OFF position.
3. Engine switch is in OFF position.
4. Engine oil is low.
5. Out of fuel.
6. Bad fuel, engine stored without
treating or draining gasoline, or
refueled with bad gasoline.
7. Spark plug is faulty or improperly
gapped.
8. Engine is flooded.
9. Spark plug fouled/fails to produce
a spark.
10. Fuel filter restricted, carburetor
malfunction, ignition malfunction,
valves stuck, etc.
1. Move choke to CLOSED position until warm,
then move to the OPEN position.
2. Move to ON position
3. Move to ON position
4. Fill with the recommended oil to the
proper level.
5. Refuel.
6. Drain fuel tank and carburetor. Refuel with
fresh gasoline.
7. Gap or replace spark plug
8. Move choke to OPEN/RUN position
9. Remove and clean spark plug. Check
electrode spacing and set the gap to the
correct dimension. Replace spark plug if
damaged. Ensure the spark lead is installed
and wire is connected.
10. Replace or repair faulty components
as needed. Contact Princess Auto Ltd
or take engine to an authorized service
center if necessary.
Engine will not
start, electric
start.
1. Power cord damaged.
2. Battery dead.
3. Fuse tripped.
4. Breaker tripped.
1. Repair or replace power cord.
2. Recharge or replace battery.
3. Replace fuse.
4. Reset breaker.
Engine lacks
power.
1. Filter element restricted.
2. Stale fuel, engine stored
without treating or draining
ethanol based gasoline.
3. Fuel filter restricted, carburetor
malfunction, ignition malfunction,
valves stuck, etc.
1. Clean or replace filter element.
2. Drain fuel tank and carburetor. Refuel with
fresh gasoline.
3. Replace or repair faulty components as
needed. Contact Princess Auto Ltd. or
take engine to an authorized service
center if necessary.
No power
generated
1. Main switch is not closed.
2. Contact of socket is not sufficient.
3. Rated speed of generator cannot
be reached.
1. Turn main switch to ON position.
2. Adjust the feet of the socket.
3. Adjust according to requirement in manual.
Visit www.princessauto.com for more information
17