8630741
6,500W Gasoline Generator with Electric Start
V1.0
MAINTENANCE SCHEDULE
This schedule applies to normal operating conditions. If you operate your engine under severe
conditions, such as sustained high-load or high-temperature operation or use in unusually wet or
dusty conditions, consult a qualified technician for recommendations applicable to your individual
needs and use.
REGULAR SERVICE PERIOD *
BEFORE
EACH USE
FIRST
MONTH OR
20 HOURS
EVERY 3
MONTHS
OR 50
HOURS
EVERY 6
MONTHS
OR 100
HOURS
EVERY
YEAR
OR 300
HOURS
Performed at every indicated month or
operating hour interval, whichever
comes first.
Engine Oil
Check
X
Change
X
X
Air Cleaner
Check
X
Clean
X **
Sediment Cup
Clean
X
Spark Plug
Clean / Adjust
X
Replace
X
Idle Speed
Check / Adjust
X
Valve Clearance
Check / Adjust
X
Combustion Chamber Clean
After every 500 Hours
Fuel Tank and Filter
Clean
X
Fuel Tube
Check
Every 2 years (replace if necessary)
* For commercial use, log hours of operation to determine proper maintenance intervals.
** Service more frequently when used in dusty areas.
TESTING AND RESETTING THE GFCI OUTLET
Test the GFCI outlet with a GFCI tester. Read the GFCI tester instructions on how to interpret
the light code.
If you don’t have a GFCI tester, plug a device, like a lamp or radio, into a working outlet. Turn
the device on to confirm it works. Switch it off and unplug it. Use this to test the outlet.
1. Start the generator.
2. Plug the GFCI tester into the GFCI outlet and read the codes.
2.1
If using a device, plug it into the GFCI outlet and switch it on.
3. The tester should show the outlet is working correctly or the device will be on.
4. Press the Test Button to trip the GFCI outlet.
4.1
The tester should show the GFCI outlet has no power. The device plugged into the
outlet will shut off. This indicates the outlet is correctly wired
4.2 Press the Reset button and power will return.
5. Power remains on after the Test Button is pressed. Follow these steps to resolve the issue.
5.1
Press the Test Button again to confirm it was activated.
5.2 Check the tester light code to see if it indicates the issue. Take steps to fix the
indicated problem.
5.2.1 If using a device, stop the generator and disconnect the device. Plug the device
into a working outlet to confirm the device is not the problem.
5.3 Consult with a qualified electrician to replace the faulty GFCI outlet with a new GFCI outlet.
10