![Pro-face PS-4600 Series User Manual Download Page 132](http://html1.mh-extra.com/html/pro-face/ps-4600-series/ps-4600-series_user-manual_1605177132.webp)
Hardware Modifications
132
UPS Interface Board Description
Overview
The figure shows the UPS Interface Board:
UPS Interface Module Description
NOTE:
The UPS Interface Board can only be operated in interface module slot 1
(see page 126)
.
The table provides the technical data for the UPS Interface Board integrated in the
Industrial Personal Computer:
The UPS Interface Board is installed using the materials included in the delivery. For
more information regarding installation, see Interface module installation
(see page 125)
.
Features
Values
Power Consumption
Max. 15 W at 0.5 A
Charging Current
Typ. 0.5 A / Max. 1 A
Deep Discharge Protection
Yes
Short Circuit Protection
Yes
Power Requirements
Max. 15 W
Status Indicators
Via the system monitor
(see page 174)
Configuration
Via the system monitor settings
(see page 174)