Main Power Connection
69
Wiring and Connecting the Terminal Block (DC power supply connector)
When wiring and connecting the PS-B unit power cables, follow the procedure
below:
Step
Action
1
Remove all power from the PS-B unit and confirm that the DC power supply
has been disconnected from its power source.
2
Connect the power cord to the terminal block as shown below:
Insert each pin terminal into its designated hole and tighten the screw with a
small slot screw driver.
Use wire with
copper conductors only
cross-section 0.75 mm² to 2.0 mm² (AWG18 to AWG14)
maximum operating temperature not less than 75
C (167
F)
3
Place the terminal block in the power connector and tighten the screws. The
recommended torque to tighten these screws is 0.5 N•m (4.5 lb-in):
3RZHUFRUG
7HUPLQDO EORFN
9
)*
9
VFUHZ
7HUPLQDO%ORFN
6FUHZ
6FUHZ
3RZHU&RQQHFWRU
3RZHU&RUG
Summary of Contents for PS-4000B Series