background image

REV:

AA 2017 12 21

-

-

/

EN

1 (2)

MODEL CODE DESCRIPTION:

TECHNICAL DATA:

¹⁾ Preferred operating direction at half displacement.

²⁾ Intermittent operation: Permissible values for maximum 10 % of every minute.

³⁾ If pilot pressure is over 30 bar

 (435 PSI)

, the pilot line should be throttled.

⁴⁾ Allowed operating temperature depends on hydraulic fluid viscosity at operating temperature.

⁵⁾ The motor load capacity must be estimated for every application.

⁶⁾ Declared values are for reference only. Always use application specific tightening torques when given.

⁷⁾ Strength class as in ISO 898-1. If using lower strength class, check interface load capacity and tightening torque.

Black Bruin Inc.

www.blackbruin.com

12.9

10.9

12.9

500

325

25 - 50

15

< 70

85

285

15

.

4

l/min

cSt

cSt

°C

°C

kg

t

Nm

Nm

Hub interface

Shaft interface

Housing interface

flow direction A to B

flow direction B to A

at full displacement

at half displacement

theoretical

with 100 bar

at full displacement

at half displacement

at full displacement

at half displacement

at freewheeling

(out of freewheeling)

(constant running)

peak pressure

intermittent ²⁾

valve released

at full displacement

at half displacement

recommended

minimum

recommended

maximum

Rotating direction

Displacement

Maximum torque
Brake torque
Max. operating power

Max. rotating speed

Max. engaging speed

Min. rotating speed
Max. working pressure

Max. case pressure

Pilot pressure for internal valve

Max. flow rate

Fluid viscosity

Operating temperature ⁴⁾
Weight

Max. load capacity ⁵⁾

Tightening torques ⁶⁾ ⁷⁾

Secondary housing interface

CW

6300

3150

45100

10000

-

130

80

80

B270

0630

2N0L

GZ

Te

ch

nic

al 

in

fo

rm

atio

co

nta

in

ed

 in

 th

is 

pu

blic

atio

is 

su

bj

ec

t to

 ch

an

ge

 at 

an

y tim

w

ith

ou

t p

rio

r n

ot

ice

. F

or

 th

lat

es

t in

fo

rm

atio

vis

it 

ou

r w

eb

site

 o

r c

on

ta

ct 

th

m

an

uf

ac

tu

re

r o

r its

 re

pr

es

en

ta

tiv

e.

B200 SERIES HYDRAULIC MOTOR

A

B

C

D

average

intermittent

valve engaged

400

2

10

7 - 30

bar

bar

bar

l/min

[email protected]

See 'B200 product manual' for more information

2-speed valve

Left side - CCW preferred

No brake

Fittings for regular lubrication

6300 ccm/rev

B270

MODEL CODE

A

B

C

D

Frame

=

=

=

=

Displacement

Displacement control

Accessory

105

ccm

ccm

Nm

Nm

kW

kW

rpm

rpm

CCW

350

40

2

450

¹⁾

rpm

rpm

rpm

bar

bar ³⁾

bar

0 - 2

Nm

650

275

728

M22x1,5

M20x1,5

Nm

330

M16x2,0

M16x2,0

10.9

384

 

cubic in

/rev

384 cubic in

192 cubic in

33,264 ft-lbs

7,376 ft-lbs

1450 PSI

174  hp

107 hp

6,527 PSI

5,802 PSI

2

9 PSI

1

45 PSI

102

 - 

135 PSI

0 - 2

9  PSI

132 GPM

86 GPM

158

°

F

1

85 °

F

628 lbs

1

6.9 T

537 ft-lbs

479 ft-lbs

203 ft-lbs

243 ft-lbs

785.856.2661

WWW.PRO-DIG-USA.COM

11

DDT25K

DDT25K

TECHNICAL DATA

MODEL CODE DESCRIPTION 

Summary of Contents for DDT25K

Page 1: ...n Manual Owners Manual Safety Precautions Manual number PRODDT25K Release Date March 1 2021 Operating Instructions Maintenance Parts Lists AUGER ANCHOR DRIVE DIRECT DRIVE DDT25K 785 856 2661 WWW PRO D...

Page 2: ...vice Dealer or the factory always have the model number and serial number of your product available These numbers will help provide exact information about your specific product You will find the mode...

Page 3: ...g or working on this equipment Know and obey all OSHA regulations local laws and other professional guidelines for your operation Know and follow good work prac tices when assembling maintaining repai...

Page 4: ...operation Replace parts that are cracked chipped or damaged in any way before operation Keep others away when making any adjustments to the unit Damage to the PRO DIG Auger Drive and auger bit can res...

Page 5: ...king a hard object underground with the auger turning can result in the slowing or stopping of the auger SAFETY DECAL LOCATIONS SAFETY DECALS This unit comes equipped with all safety decals in place T...

Page 6: ...the hole 6 Stop rotation of the auger and raise the auger out of the hole Swing the auger away from the newly drilled hole Spin the loose material off the auger Note Do not reverse the auger rotation...

Page 7: ...79 60 120 120 454 72 144 130 492 78 156 OUTPUT TORQUE PRESSURE HIGH SPEED LOW SPEED PSI BAR ft lbs Nm ft lbs Nm 500 34 1274 1727 2548 3455 750 52 1911 2591 3822 5182 1000 69 2548 3455 5096 6909 1250 8...

Page 8: ...66 12103 12740 Lo S pd Hi T qe Ft L bs 2548 3822 5096 6370 7644 8918 10192 11466 12740 14014 15288 16563 17837 19111 20385 21659 22933 24207 25481 0 5000 10000 15000 20000 25000 30000 Torque Ft Lbs DD...

Page 9: ...S pd Hi T qe Nm 3455 5182 6909 8637 10364 12092 13819 15546 17274 19001 20728 22456 24183 25911 27638 29365 31093 32820 34547 35073 0 5000 10000 15000 20000 25000 30000 35000 40000 Torque Ft Lbs DDT25...

Page 10: ...10 WWW PRO DIG USA COM DDT25K...

Page 11: ...mum Rotating direction Displacement Maximum torque Brake torque Max operating power Max rotating speed Max engaging speed Min rotating speed Max working pressure Max case pressure Pilot pressure for i...

Page 12: ...12 MAIN DIMENSIONS DDT25K WWW PRO DIG USA COM...

Page 13: ...785 856 2661 HYDRAULIC CONNECTIONS 13 DDT25K...

Page 14: ...14 DDT25K WWW PRO DIG USA COM...

Page 15: ...785 856 2661 15 DDT25K...

Page 16: ...16 WWW PRO DIG USA COM DDT25K 2 C...

Page 17: ...17 DDT25K 785 856 2661...

Page 18: ...a period of ten days from the Company issuing a Report thereon the goods remain uncollected or no written instructions are received in relation thereto 2 The liability of the Company for all goods or...

Page 19: ...785 856 2661 NOTES DDT25K 19...

Page 20: ...1604 ROSEPORT RD ELWOOD KS 66024 785 856 2661 WWW PRO DIG USA COM PROUD MEMBER OF...

Reviews: