LIMITED WARRANTY 

    

Pro Charging Systems, LLC (PCS) makes this Limited Warranty only to the original retail purchaser.

  

 

    

PCS warrants this battery charger for three years (unless the charger is used outside of the USA or the charger has a part number with 
the RM designation) from the date of retail purchase against defective materials and/or workmanship.

 

 *

-

RM suffix refers to 

Restricted Markets

” 

such as Rental applications and Heavy Industrial applications.

 

 These chargers, along with any chargers used 

outside of the USA, will have a warranty period of 18 months from the date of retail purchase against defective materials and/or 
workmanship.

 

 CR refers to 

Certified Reconditioned

” 

and designates a 1 year warranty.

    

 

    

If such defects should occur, this unit will either be repaired or replaced at the discretion of the manufacturer.

 

 It is the responsibility 

of the original purchaser to return the charger along with proof of purchase, transportation, and/or any mailing or handling charges 
prepaid to the manufacturer or its authorized representative.

 

 Chargers that are purchased more than two years beyond the date of 

production will automatically have a warranty start date that will be the two year anniversary of the production date. 

    

This limited warranty is void if the product is misused, improperly maintained, handled carelessly or incorrectly operated.

  

 

Additionally, this warranty is void if the charger is disassembled, the charger

s charge cables are cut, the power cord is cut off, the 

charger is altered without authorization from PCS, the serial number is removed, or repair is attempted by anyone other than an au-
thorized representative.

  

 

    

PCS makes no other warranty other than this limited warranty and expressly excludes any implied warranty, including warranty for 
any incidental or consequential damages.

 

 This is the only expressed limited three year warranty authorized by PCS and does not au-

thorize anyone to assume or make any other obligation towards the product other than this three year Limited Warranty.

 

 Some 

states do not allow limitation of incidental or consequential damages. This warranty gives you specific legal rights and you may also 
have other rights which vary from state to state. 

    

Please call Pro Charging Systems, LLC for full warranty information at 

(615.471.5300)

.

  

 

    

VEHICLE LOCKOUT CONTROL OPTION

 

INHIBIT (LOCKOUT) WIRING

 

 

SW1

 

WHITE

 

BLACK

 

 

When charging, SW1 is open.

 

When not charging SW1 is closed.   

 

 

SW1 maximum current = 3Adc

 

 

AC CONVENIENCE PORT ACCESORY OPTION

 

• 

This option is mounted on equipment or vehicle body and allows an A.C. extension Cord to 
connect to it, where the charger is mounted deep inside the vehicle. It provides a 5

-

LED 

Status display. This option is not available for 

R

-

Series

’ 

charger products. 

For component 

information, please scan the following QR code:

 

• 

The circuit depicted above, when applied as an application with the equipment or vehicle, will prevent the           
operating of that equipment or vehicle while the charger is connected to A.C. Utility Power.

 

• 

The White connection on the vehicle side is connected to battery positive (+).  Max voltage 100VDC.

 

• 

The Black connection on the vehicle side is connected to the lockout contactor.

 

• 

For products with 

Pigtail

’ 

Lockout Inhibit Cable already installed, a tethered output pigtail is in-

cluded on some models and exits the front of the charger.  

For component information, please 

scan the following QR code:

 

Summary of Contents for DUAL PRO Patriot PS2420

Page 1: ...cal Support Group at 615 471 5300 Or email us at tech pcsdv com 70384 091222 Safety Installation and Operating Instruction Instructions importantes concernant la securite Patriot Series 2420 High Freq...

Page 2: ...INSTRUCTIONS INSTRUCTIONS IMPORTANTES CONCERNANT LA S CURIT SAVE THESE INSTRUCTIONS This manual contains important safety and operating instructions for future reference CONCERVER CES INSTRUCTIONS CE...

Page 3: ...h Keep proper footing and balance at all times Do not reach over or across electrical cables or frames Avoid Electrical Shock To reduce risk of electrical shock unplug charger from outlet before attem...

Page 4: ...contact with eyes Add distilled water to each cell until battery acid reaches level specified by battery manufacturer This helps purge excessive gas from cells Do not overfill For a battery without c...

Page 5: ...ilated Connect your extension cord with no AC Power present to the battery charger and proceed to plug your extension cord into a 120VAC GFCI protected Ground Fault Circuit Interrupt outlet Risk of el...

Page 6: ...rmal operation For this reason it is of the utmost importance that prior to each use of your charger you read and follow the instructions provided exactly Il est dangereux de travailler a proximit d u...

Page 7: ...yes Wear eye and clothing protection and avoid touching eyes If battery acid contacts skin or clothing wash immediately with soap and water If acid enters eye immediately flush eye with running cold w...

Page 8: ...neral wear including loose or hanging receptacles and be very aware of potentially worn contacts If any heat is felt in and around the receptacle while the charger is operating this is an immedi ate i...

Page 9: ...n mating contact surfaces are worn or dirty Replace receptacle or charger plug or both when worn It is also highly suggested to periodically replace the plug and receptacle every three years but subje...

Page 10: ...075 125 2 400 0 1 1 1 0 16 PsZ Cell Lead Acid Flooded 125 175 2 400 0 1 1 1 1 17 PsZ Cell Lead Acid Flooded 200 250 2 400 1 0 0 0 0 18 PsZ Cell Lead Acid Flooded 300 350 2 400 1 0 0 0 1 19 PsZ Cell Le...

Page 11: ...OR TABLE LED s Left to Right LED s Left to Right Note Once the charging algorithm MODE has been changed there will be a longer than normal startup time up to 10 minutes for the first use after the alg...

Page 12: ...e has terminated its normal operation prematurely An abnormal charging condition was detected and charging stopped due to a Charge Error Condition Refer to the following Charge Error Table for an exte...

Page 13: ...ror 1 0 0 1 1 19 Battery Testing Error Sulphated 1 0 1 0 0 20 Battery Testing Error Discharged 1 0 1 0 1 21 Bulk Charge Safety Time Error 1 1 0 0 1 25 Absorption Safety Time Error 1 1 0 1 0 26 Excessi...

Page 14: ...amperage An overcharged cell due to other cells being unbalanced and at a much lower state of charge Possible corrections include Cease charging operate vehicle to slightly discharge battery pack then...

Page 15: ...s are left in storage for a lengthy period months Charger should be connected to AC Power continually or periodically once per month to replenish batteries self discharged condition to prevent possibl...

Page 16: ...anyone other than an au thorized representative PCS makes no other warranty other than this limited warranty and expressly excludes any implied warranty including warranty for any incidental or conse...

Reviews: