To reduce risk of battery explosion, follow these instructions, those published by the 

 

battery manufacturer, and by the manufacturer of any equipment that you intend to use in 

the vicinity of battery. Review all cautionary markings on these products and on the 

 

engine. 

 

Pour réduire le risque d

explosion, lire ces instructions et celles qui figurent sur la batterie. 

 

If it is necessary to relocate the battery for charging, first remove the grounded terminal from the battery. 
Then make sure all accessories are off, so as not to cause battery arcing.

 

 

RISK OF EXPLOSIVE GASES: WORKING IN THE VICINITY OF A LEAD

-

ACID BATTERY IS DANGER-

OUS. 

Batteries generate explosive gases during normal battery operation. For this reason, it 

is of utmost importance that prior to each use of your charger, you read this manual and follow the instruc-
tions exactly. 

Il est dangereux de travailler a proximité d

une batterie au plomb. Les batteries produisent des gaz 

explosifs en service normal. Il est aussi important de toujours relire les instructions avant d

utiliser le chargeur et 

de les suivre à la lettre. 

 

 

Do not operate charger in a closed

-

in area or restrict ventilation in any way. 

 

Ne pas faire fonctionner le chargeur dans un espace close et/ou ne pas gener la ventilation. 

 

 

Clean battery terminals. Be careful to keep corrosion from coming into contact with eyes. Add distilled water to 
each cell until battery acid reaches level specified by battery manufacturer. This helps purge excessive gas from 
cells. Do not overfill. For a battery without cell caps, carefully follow manufacturer

s recharging instructions. 

Study all battery manufacturers

’ 

specific precautions such as removing or not removing cell caps while charging 

and recommended rates of charge. 

 

 

When using an extension cord, make sure: 

 

 

• 

that pins on plug of extension cord are the same number, size, and shape as those of the charger

 

plug; 

 

 

• 

that extension cord meets UL (Underwriters Laboratories, Inc.) acceptance; 

 

 

• 

that wire size is large enough for AC ampere rating of charger. 

 

Always make your extension cord connection on the charger side before connecting to a near-
by 

120VAC GFCI protected (Ground Fault Circuit Interrupt) outlet. Failure to use a GFCI out-

let may result in electrical shock. Note:  U(Universal) chargers should be connected to a 110, 115 or 230VAC 
GFCI protected outlet. The DC connection should always be made before connecting or disconnecting the AC 
side. 

 

Note: Extension cords should be industrial grade/heavy duty UL approved and grounded. Check extension cord 
before use for damage, bent prongs and cuts. Replace if damaged. 

 

Connect the extension cord to the charger; then proceed to plug the extension cord to the GFCI protected 
(Ground Fault Circuit Interrupt) outlet. 

 

Always remove the extension cord from the GFCI protected outlet first when charging is completed, followed by 
unplugging the charger. 

 

Summary of Contents for DUAL PRO Patriot PS2420

Page 1: ...cal Support Group at 615 471 5300 Or email us at tech pcsdv com 70384 091222 Safety Installation and Operating Instruction Instructions importantes concernant la securite Patriot Series 2420 High Freq...

Page 2: ...INSTRUCTIONS INSTRUCTIONS IMPORTANTES CONCERNANT LA S CURIT SAVE THESE INSTRUCTIONS This manual contains important safety and operating instructions for future reference CONCERVER CES INSTRUCTIONS CE...

Page 3: ...h Keep proper footing and balance at all times Do not reach over or across electrical cables or frames Avoid Electrical Shock To reduce risk of electrical shock unplug charger from outlet before attem...

Page 4: ...contact with eyes Add distilled water to each cell until battery acid reaches level specified by battery manufacturer This helps purge excessive gas from cells Do not overfill For a battery without c...

Page 5: ...ilated Connect your extension cord with no AC Power present to the battery charger and proceed to plug your extension cord into a 120VAC GFCI protected Ground Fault Circuit Interrupt outlet Risk of el...

Page 6: ...rmal operation For this reason it is of the utmost importance that prior to each use of your charger you read and follow the instructions provided exactly Il est dangereux de travailler a proximit d u...

Page 7: ...yes Wear eye and clothing protection and avoid touching eyes If battery acid contacts skin or clothing wash immediately with soap and water If acid enters eye immediately flush eye with running cold w...

Page 8: ...neral wear including loose or hanging receptacles and be very aware of potentially worn contacts If any heat is felt in and around the receptacle while the charger is operating this is an immedi ate i...

Page 9: ...n mating contact surfaces are worn or dirty Replace receptacle or charger plug or both when worn It is also highly suggested to periodically replace the plug and receptacle every three years but subje...

Page 10: ...075 125 2 400 0 1 1 1 0 16 PsZ Cell Lead Acid Flooded 125 175 2 400 0 1 1 1 1 17 PsZ Cell Lead Acid Flooded 200 250 2 400 1 0 0 0 0 18 PsZ Cell Lead Acid Flooded 300 350 2 400 1 0 0 0 1 19 PsZ Cell Le...

Page 11: ...OR TABLE LED s Left to Right LED s Left to Right Note Once the charging algorithm MODE has been changed there will be a longer than normal startup time up to 10 minutes for the first use after the alg...

Page 12: ...e has terminated its normal operation prematurely An abnormal charging condition was detected and charging stopped due to a Charge Error Condition Refer to the following Charge Error Table for an exte...

Page 13: ...ror 1 0 0 1 1 19 Battery Testing Error Sulphated 1 0 1 0 0 20 Battery Testing Error Discharged 1 0 1 0 1 21 Bulk Charge Safety Time Error 1 1 0 0 1 25 Absorption Safety Time Error 1 1 0 1 0 26 Excessi...

Page 14: ...amperage An overcharged cell due to other cells being unbalanced and at a much lower state of charge Possible corrections include Cease charging operate vehicle to slightly discharge battery pack then...

Page 15: ...s are left in storage for a lengthy period months Charger should be connected to AC Power continually or periodically once per month to replenish batteries self discharged condition to prevent possibl...

Page 16: ...anyone other than an au thorized representative PCS makes no other warranty other than this limited warranty and expressly excludes any implied warranty including warranty for any incidental or conse...