Use charger for charging a LEAD

-

ACID (lead acid, sealed lead acid, gel cell and AGM) battery 

only. It is not intended to supply power to a low voltage electrical system other than in a 
starter

-

motor application. Do not use battery charger for charging dry

-

cell batteries that are 

commonly used with home 

 

appliances. These batteries may burst, causing personal injury and damage to property. 

 

Utiliser le chargeur pour charger une batterie au plomb uniquement. Ce chargeur n

est pas concu pour alimenter 

un réseau électrique très basse tension ni pour charger des piles sèches. Le fait d

utiliser le charger des piles sèch-

espourait entrainer l

éclatement des piles et causer des blessures ou des dommages. 

 

 

DO NOT attempt to attach a charger to a battery pack if the output of the charger does not match the battery 
pack voltage. Example: Model i

-

3625 is a 36 volt output charger and is only usable on 36 volt battery systems. 

NEVER connect to just one battery (ie. 6V) in the pack. Damage can occur. 

 

 

Be extra cautious to reduce risk of dropping a metal tool onto battery. It might cause a spark or short

-

circuit a 

battery or other electrical part, possibly resulting in an explosion. If damaged, contact PCS 
(

615.471.5300

). 

 

NEVER charge a frozen battery. 

 

Ne jamais charger une batterie gelée. 

 

Assure that the area around your charger and batteries is properly ventilated. Connect your extension cord, with 

no AC Power present, to the battery charger and proceed to plug your extension cord into a 
120VAC GFCI protected (Ground Fault Circuit Interrupt) outlet. 

 

Risk of electrical shock! Do not touch uninsulated parts of the battery charger output 

 

connector, battery connector, or battery terminals. 

 

Once you plug in your PCS battery charging system, the charge cycle will begin automatically. 
State of charge will be displayed by illumination of the Light Emitting Diodes (LEDS) on the 
battery status indicator located on the front of the unit. 

 

DO NOT connect or disconnect the DC output electrical cord to or from the battery 

 

receptacle when the charger is on. Arcing and / or burning of the plug and receptacle could result and could 
cause the batteries to explode. If the charger must be stopped, first 

 

disconnect the AC power supply cord from its outlet, then disconnect the charger DC output 
plug from the battery receptacle.

 

We recommend that you leave your system plugged in. This will reduce sulfation on the lead 
plates of the batteries and allow your PCS charging system to keep your batteries fully main-
tained and ready to perform at their best. 

 

Study all battery manufacturers

’ 

specific precautions such as removing or not removing cell caps while charg-

ing and recommended rates of charge. 

 

Prendre connaissance des measures de précaution spécifiés par le fabricant de la batterie, p. ex., vérifier s

il faut 

enlever les bouchons des cellules lors du chargement de la batterie, et les taux de chargement recommandés. 

 

 

Summary of Contents for DUAL PRO Patriot PS2420

Page 1: ...cal Support Group at 615 471 5300 Or email us at tech pcsdv com 70384 091222 Safety Installation and Operating Instruction Instructions importantes concernant la securite Patriot Series 2420 High Freq...

Page 2: ...INSTRUCTIONS INSTRUCTIONS IMPORTANTES CONCERNANT LA S CURIT SAVE THESE INSTRUCTIONS This manual contains important safety and operating instructions for future reference CONCERVER CES INSTRUCTIONS CE...

Page 3: ...h Keep proper footing and balance at all times Do not reach over or across electrical cables or frames Avoid Electrical Shock To reduce risk of electrical shock unplug charger from outlet before attem...

Page 4: ...contact with eyes Add distilled water to each cell until battery acid reaches level specified by battery manufacturer This helps purge excessive gas from cells Do not overfill For a battery without c...

Page 5: ...ilated Connect your extension cord with no AC Power present to the battery charger and proceed to plug your extension cord into a 120VAC GFCI protected Ground Fault Circuit Interrupt outlet Risk of el...

Page 6: ...rmal operation For this reason it is of the utmost importance that prior to each use of your charger you read and follow the instructions provided exactly Il est dangereux de travailler a proximit d u...

Page 7: ...yes Wear eye and clothing protection and avoid touching eyes If battery acid contacts skin or clothing wash immediately with soap and water If acid enters eye immediately flush eye with running cold w...

Page 8: ...neral wear including loose or hanging receptacles and be very aware of potentially worn contacts If any heat is felt in and around the receptacle while the charger is operating this is an immedi ate i...

Page 9: ...n mating contact surfaces are worn or dirty Replace receptacle or charger plug or both when worn It is also highly suggested to periodically replace the plug and receptacle every three years but subje...

Page 10: ...075 125 2 400 0 1 1 1 0 16 PsZ Cell Lead Acid Flooded 125 175 2 400 0 1 1 1 1 17 PsZ Cell Lead Acid Flooded 200 250 2 400 1 0 0 0 0 18 PsZ Cell Lead Acid Flooded 300 350 2 400 1 0 0 0 1 19 PsZ Cell Le...

Page 11: ...OR TABLE LED s Left to Right LED s Left to Right Note Once the charging algorithm MODE has been changed there will be a longer than normal startup time up to 10 minutes for the first use after the alg...

Page 12: ...e has terminated its normal operation prematurely An abnormal charging condition was detected and charging stopped due to a Charge Error Condition Refer to the following Charge Error Table for an exte...

Page 13: ...ror 1 0 0 1 1 19 Battery Testing Error Sulphated 1 0 1 0 0 20 Battery Testing Error Discharged 1 0 1 0 1 21 Bulk Charge Safety Time Error 1 1 0 0 1 25 Absorption Safety Time Error 1 1 0 1 0 26 Excessi...

Page 14: ...amperage An overcharged cell due to other cells being unbalanced and at a much lower state of charge Possible corrections include Cease charging operate vehicle to slightly discharge battery pack then...

Page 15: ...s are left in storage for a lengthy period months Charger should be connected to AC Power continually or periodically once per month to replenish batteries self discharged condition to prevent possibl...

Page 16: ...anyone other than an au thorized representative PCS makes no other warranty other than this limited warranty and expressly excludes any implied warranty including warranty for any incidental or conse...