4. Using a nut driver remove nut (A) which secures probe
bracket (B) to screw (C) on the control box.
See figure 23.
5. Remove probe bracket (A) and carefully slide probe (B)
out of the platen tube. Discard old probe assembly.
See figure 24.
6. Install new probe by reversing steps 2 through 5. For
probe replacement in the lower control box follow these
same instructions.
figure 23
B
figure 24
Model No. 78-166S Power Switch
Tools needed: 1/4” Flat Blade Screwdriver.
1. Lower toaster to toast position. Using 1/4” Flat
Blade Screwdriver remove (2) screws (A) from
the lower control box and lift off cover. See
figure 25.
2. Disconnect (4) wire connections (A) from the
power switch (B). See figure 26.
3. Remove power switch by squeezing bezel clips
on switch (A) and pushing switch (B) out of the
control box. See figure 27.
4. To install new power switch reverse steps 1-3.
Make sure all wire connections are
tight and on the right posts.
Top Left
=
Brown Wires
Bottom Left
=
Black Wire
Top Right
=
Double Black Wire
Bottom Right
=
Double Red Wire
figure 25
figure 26
figure 27