CLEANING
CAUTION:
Before unplugging power cord
make sure the toaster power switch is
turned OFF.
1. Unplug toaster power cord from outlet.
2. Allow toaster to cool.
3. Follow cleaning instructions.
IMPORTANT:
Always lock platens in open position
using the safety latch before cleaning or relocating
toaster to a different location.
IMPORTANT:
When cleaning do not pour water on
the platen. This may cause an electrical hazard and
cause serious damage to the sensitive solid state
circuitry in this toaster.
REMOVAL & CLEANING OF
RELEASE SHEETS
TO REMOVE:
1. Toaster must be cold before release sheets can
be removed.
CAUTION:
Before removing release
sheets the toaster platen must be locked
in its open position by engaging the
“safety latch”.
2. Remove release sheets by removing the round
bar from the spring clip on the front of platens
and then remove the stretcher bar from rear
hooks.
3. Remove stretcher bar from release sheets.
TO CLEAN:
1. Lightly scrub the release sheet on both sides
using a damp clean towel. Keep sheet flat while
cleaning to ensure no wrinkles or creases are
put into sheet.
IMPORTANT:
Do not use green pads to scrub
release sheets.
PROBLEM
PROBABLE CAUSE
CORRECTIVE ACTION
Platen Has excessive movement.
Platen attachment bolts loose.
Tighten bolts.
Audio Alarm works, no amber
Light burned out.
Replace amber colored bun done
colored bun light.
light.
No audio alarm or amber colored
Speaker defective.
Replace speaker.
bun done light.
Opto sensor board defective.
Replace opto sensor board.
Buns being crushed.
Stop blocks not adjusted properly
Adjust stop blocks.
Buns cut improperly.
Adjust stop block to (=) or (-).
Buns sticking to platen.
Excessive heat.
Calibrate toaster.
Built up carmelized sugar on platen. Clean platen (PM Card #17).
One platen not heating but no
Corresponding probe inoperable.
Replace probe.
diagnostic signals.
TROUBLESHOOTING CHART
CAUTION:
Service is to be performed by
qualified service personnel.
CAUTION:
Use extreme caustion during
electrical ciruit tests. Live circuits will be
exposed.
CAUTION:
Inspection, testing and repair of
electrical equipment should be performed
only by qualified service personne. The unit
should be unplugged when servicing, except
when electrical tests are required.
5
2. Rinse release sheets using clean running water
and wipe the sheets dry in one direction only
using a clean damp grill cloth until all residue is
removed. Do not fold or crease (air dry).
3. Rinse release sheets using clean running water
and wipe the sheets dry in one direction only
using a clean damp grill cloth. Keep wiping until
all residue is removed.
Summary of Contents for Excalibur 411-SL Series
Page 12: ...WIRING DIAGRAM 12...