14
INSTALLATION AND MAINTENANCE MANUAL
516574_C_PUB_DATE_3_NOV_2009.DOC
1. Plug of emergency drain
2. Pump cover
Fig. 5.1. Drain pump
3. Check for the belt tightness or possible damage; therefore remove the machine rear cover.
4. Check visually all hoses and connection inside the machine for leaking.
5. Check the condition and tightness of bolt joints (fig.5.2.C,pos.7 and 8) which hold the trunnion.
5.2. ADJUSTMENTS AND PART'S EXCHANGES
ADJUSTMENT OF DOOR SEAL THRUST
1. For increasing (resp. decreasing) the pressure of the door seal, take off spacers (3) (resp. add spacers)
between the door frame and the hinge blocks. Therefore remove the screws (6) on the door frame.
Tighten the screws again after positioning the spacers.
2. The adjustments of the door seal pressure must be executed as follows. The door rubber (4) must still
touch the tub rubber at the hinge side when the door opens at 5°.
3. Adjust the position of the door by loosening the screws (6) on the door frame. The door hook (1) must be
right in the center of the door lock opening. Tighten the screws (6) again after correct positioning of the door.
4. If necessary, take of spacers (2) (resp. add spacers) between the door latch (1) and the door frame to
achieve a good door pressure and a normal force for closing the door.
1. Door hook
2. Adjusting spacers of the door latch
3. Adjusting spacers of the door hinge
4. Door seal
5. Door glass
6. Bolts of the door hinge
7. Door frame
Fig.5.2.A Door fastening