INSTALLATION AND MAINTENANCE MANUAL
5
HEATING
Types of heating:
cold soft / hot soft water
- without electric heating
cold soft / additional hot soft water
- with electric heating 2750 W
- with electric heating 6000 W
- with electric heating 9000 W
CONNECTION
WATER CONNECTION:
water pressure
water inlet
maximal water temperature
0.1 - 0.8 MPa / 1-8bar / 14.5 - 116 PSI
3/4“
70°C / 158°F
CONNECTION OF WATER DRAINAGE:
via drain valve diameter
flow amount with drain valve
via drain pump, hose diameter
flow amount with drain pump
51 mm / 2“
52 dm
3
min
-1
/ 14 gal min
-1
33.5 mm / 1.32“
36 dm
3
min
-1
/ 9.5 gal min
-1
Soap hoppers:
1 with 3 chambers
CONSUMPTION
AVERAGE WATER CONSUMPTION WITHOUT PREWASH :
wash bath temperature 60°C, normal low level at main
wash, normal high level at rinse
AVERAGE WATER CONSUMPTION WITH PREWASH :
wash bath temperature (35°C - prewash, 60°C - main wash),
normal low level for prewash and main wash, normal high
level for rinse
106,3 l
128,7 l
118,7 l
144,3 l
AVERAGE ELECTRICAL POWER CONSUMPTION
WITHOUT PREWASH :
wash bath temperature 60°C
AVERAGE ELECTRICAL POWER CONSUMPTION
WITH PREWASH :
wash bath temperature (35°C - prewash, 60°C - main wash)
100% electric heating
2,14 kWh
2,58 kWh
100% electric heating
2,15 kWh
2,60 kWh
WORKING CONDITIONS
ambient temperature
relative humidity
height above sea level
from + 5 ° C (41°F) to + 35 °C (95°F)
30 % ÷ 90 % without condensation
up to 1000 m / 3280 ft
ANCHORING
ANCHORING THE MACHINE:
free locating - in horizontal level
max. static loading of floor (with linen and water)
max. dynamic loading of floor
((alternative stress at extracting)
frequency of dynamic loading
184 kg / 405 lbs
± kg
Hz
198 kg / 437 lbs
± kg
Hz
NOISE
MEAN NOISE LEVEL AT MAX. LOADING:
70 dB (A)
maximum dimensions including protruding parts
Tab. 3.1. continue
*
Summary of Contents for 5kg
Page 2: ......
Page 30: ...20 INSTALLATION AND MAINTENANCE MANUAL 516574_C_PUB_DATE_3_NOV_2009 DOC REMARKS ...
Page 31: ......