background image

Assemble Remote Antenna

1. For vertical mount, connect the BNC cable adapter to the straight connector. For horizontal mount, remove the straight

connector and connect the BNC cable adapter to right-angle connector. Push the adapter onto the connector and turn

connector 1/4 turn to lock into place.

NOTE

Antenna is required to be in a vertical position.

2. Connect the antenna to the other end of connector.

3. Use the two screws to securely mount bracket to wall surface.

34

XR Classic Series Digital Clocks/Timers Install Guide

Summary of Contents for XR Classic Series

Page 1: ...ark of Primex All other trademarks are the property of their respective owners 12 3 2018 Primex Inc 965 Wells Street Lake Geneva WI 53147 www primexinc com Ph 1 262 729 4853 XR Classic Series Digital...

Page 2: ...itted in any form or by any means electronic mechanical or otherwise for any purpose without the prior written permission of Primex Inc Primex Inc Primex is a leading provider of synchronized time and...

Page 3: ...lies with part 15 of the FCC rules as well as with Industry Canada Operation of this device is subject to the following two conditions l This device may not cause harmful interference l This device mu...

Page 4: ...as vases must be placed on the device l Device is designed for indoor use only Operating outdoors or in wet areas is an electrical hazard and may damage the equipment while nullifying the warranty l...

Page 5: ...s 17 120VAC Wiring 18 24VAC Wiring Guidelines 18 Surface Mount Installation 19 Tilt Bracket Installation 21 Dual Mount Installation 23 Dual Sided Digital Clock Dimensions 25 Remove Digital Clock Timer...

Page 6: ...tes 1 4 3 6 cm diagonal seconds 4 model 4 6 11 7 cm diagonal hours and minutes 2 5 6 4 cm diagonal seconds LED Display Dimmer 100 75 50 25 Time Display 12 or 24 hour time PM indicator light Alternatin...

Page 7: ...230VAC 18 Watts 5 7 cm x 4 Digit 69mA 230VAC 16 Watts 5 7 cm x 4 Digit Dual 139mA 230VAC 32 Watts 5 7 cm x 6 Digit 100mA 230VAC 23 Watts 5 7 cm x 6 Digit Dual 200mA 230VAC 46 Watts Storage Temperature...

Page 8: ...e to test any cleaning solutions on a small area Elapsed Timer Timer Switch Control operating specifications The timer has three operating modes and a set state The Timer Switch Control DISPLAY button...

Page 9: ...t time Or Holding the RESET button puts the timer into SET STATE Pressing and releasing the RESET button once automatically stops and resets the count event to its preset start time Or Holding the RES...

Page 10: ..._ _ _ _ _ _ on the display The selected digit will blink Pressing SET CHANGE again to select the next digit Code Blue Timer Timer Switch Control operating specifications The Timer Switch Control allo...

Page 11: ...roximately three minutes while the clock timer receiver is turned on to search for a Transmitter signal If the clock timer does not receive a valid signal from a Transmitter for three days its colons...

Page 12: ...on and for a 4 display set the HR Offset 12 24 HR switch 1 in the up position as illustrated below Set PM Indicator To set the PM dot indicator for a 2 5 display set the PM switch 3 to the UP position...

Page 13: ...function To enable the buzzer feature place the OPTIONS Buzzer switch 8 in the UP position as illustrated below Set Receive Channel Programmable Timer Only The Programmable Countdown Timer receives i...

Page 14: ...Transmitter Channel RF Channel Dial Transmitter Channel RF Channel Dial 7 7 15 F 8 8 16 0 14 XR Classic Series Digital Clocks Timers Install Guide...

Page 15: ...adcasts its synchronized time to the system clocks and devices from the 39th to the 6th minute of the next hour and changes to a standby mode during the 7th to the 38th minute of the hour standard bro...

Page 16: ...mA 5 0 12 7 cm 10 75 27 30 cm 2 5 6 35 cm 2 5 6 35 cm 6 digit 2 72 lb 1 23 kg 260 mA 5 0 12 7 cm 13 75 34 93 cm 2 5 6 35 cm 4 10 16 cm 4 digit 4 74 lb 2 15 kg 230 mA 8 0 20 32 cm 18 45 72 cm 3 7 62 cm...

Page 17: ...to wall surface for 18 mounting bracket Dimension G H mounting bracket screw hole spacing Single Digital Clock Timer mounting dimensions illustration Single Digital Clock Timer mounting dimension spec...

Page 18: ...26VAC For installations where 24VAC wiring exists the gauge length of the wire and rating for the supply transformer should be verified to ensure adequate current supply and voltage for all connected...

Page 19: ...of a wall Installation Mount the clock timer directly to the wall with the two 10 screws and anchors supplied NOTE Most building codes prohibit the use of hard wired power connections for devices that...

Page 20: ...20 XR Classic Series Digital Clocks Timers Install Guide...

Page 21: ...a junction box installed by a licensed electrician The tilt bracket has a center pass through hole for the 120V pigtail If a junction box is present the tilt bracket also has mounting holes spaced to...

Page 22: ...22 XR Classic Series Digital Clocks Timers Install Guide...

Page 23: ...e necessary to complete the installation Materials required not supplied l One junction box How to install a Dual Mount Digital Clock Timer 1 On the wall or ceiling measure and drill holes with the co...

Page 24: ...Dual Digital Bracket Kit flange dimension Dual Digital Clock Mounting illustration 24 XR Classic Series Digital Clocks Timers Install Guide...

Page 25: ...l 2 5 4 digit clock 13 75 34 93 cm 8 0 20 32 cm 6 6 16 76 cm Dual 2 5 6 digit clock 16 8 42 67 cm 8 0 20 32 cm 6 6 16 76 cm Dual 4 4 digit clock 21 0 53 34 cm 11 0 27 94 cm 7 5 19 05 cm Dual 4 6 digit...

Page 26: ...e bracket using a screwdriver press each hook down to release the clock Then pull out to unsnap bottom hinges 4 x 4 and 4 x 6 from the top of the bracket insert a thin screwdriver into each notch and...

Page 27: ...ock Timer Required materials AC powered models not supplied l One standard 2x4 cut to 14 5 inches 36 83 cm l Digital Clock Model one square shallow 4x4 10 16 cm x 10 16 cm junction box l Digital Timer...

Page 28: ...or the clock assembly 2 Secure a standard 2x4 cut to 14 5 inches 36 83 cm between the two studs located 0 5 inch 1 27 cm above the top of the bottom of the opening and 2 4 inches 6 0 cm from the front...

Page 29: ...ch 2 54 cm from the center of the opening and flush with the front side of the 2x4 4 Remove the clock face plate and set aside 5 Remove the four screws that secure the circuit board 6 Disconnect the c...

Page 30: ...Code Blue Timer Input wire to designated code blue system and timer control switch Elapsed Timer Input wire to timer control switch For wiring specifications see Timer Control Switch Installation on p...

Page 31: ...to increase the opening up to 0 3 inch 14 7 inches total on either side as well as 0 2 inches 5 6 inches total on the top or bottom If these adjustments still do not allow the clock assembly to be mou...

Page 32: ...board power cord connector and the timer input connector that was disconnected in step 6 15 Refasten the circuit board using the four screws previously removed 16 Peel off the protective checker boar...

Page 33: ...e clock timer assembly The remote antenna components are required to be assembled and mounted Remote Antenna components 1 Antenna 1 Mounting bracket 1 Straight connector for standard vertical mount 1...

Page 34: ...ect the BNC cable adapter to right angle connector Push the adapter onto the connector and turn connector 1 4 turn to lock into place NOTE Antenna is required to be in a vertical position 2 Connect th...

Page 35: ...is to be concealed behind the wall use a single gang electrical box to be mounted horizontally behind the clock For a straight vertical cable run a minimum of 0 5 inch 1 27 cm electrical conduit shoul...

Page 36: ...ode blue system that applies a voltage to start a code blue event wire the timer 4 pin connectors RED Positive Code Blue Input and BLACK Negative Code Blue Input wires to the code blue system An input...

Page 37: ...37...

Page 38: ...e viewed until a new code blue event is triggered l A code blue count can be halted by pressing the STOP START button Pressing either DISPLAY or RESET is ignored while in code blue mode l Triggering o...

Page 39: ...t its start time When not in a count mode the timer displays its synchronized time Specifications l When power is first applied it enters clock mode displaying its synchronized time l Count Up and Cou...

Page 40: ...it inside a single gang box not supplied typically 2 1 4 in x 2 3 4 in x 4 in 11 45 cm x 6 99 cm x 10 15 cm l Timer Switch Control can simultaneously activate two connected timers for even more accura...

Page 41: ...displays its synchronized time press and release the DISPLAY button until the current time is displayed Start a Count Down event By default the Count Down event starts at 99 hours 59 minutes 59 second...

Page 42: ...release the STOP START button to start stop or pause the count event Set Count Down start time You can set the start time using the 3 button Timer Switch Control For a count down event the default sta...

Page 43: ...process until you set the time you want to start the count down event 4 When the start time is set press and release the EXIT button to return to Count Down mode Now you can press and release the STOP...

Page 44: ...the schedule is downloaded to the system Transmitter Set Receive Channel Programmable Timer Only The Programmable Countdown Timer receives its time and schedule information from a Transmitter into wh...

Page 45: ...offer technical support services for Primex products If you have purchased Primex products or have a service agreement with a Primex Partner they are your primary contact for all Technical Support in...

Page 46: ...ntal special indirect or consequential damages whether resulting from the use misuse or inability to use this product or from defects in the product Some states do not allow this exclusion or limitati...