STEP 7
STEP 5
STEP 6
STEP 8
Loosen cam locks on diffuser to prepare filter for installation. Be sure latches are turned inwards so as not to interfere with filter frame.
NOTE:
Note location of filter alignment guides (minimum one per side, dependent on size).
Raise the filter in place using two people and being careful not
to contact the filter media.
Secure filter in place using the cam locks. Tighten until no
further rotations can be made. No tools are required to tighten,
and using one may cause damage to filter gel seal.
Ensure HEPA filter outer frame is in contact with horizontal
knife edge of frame. Note that diffuser knife edge cannot
bottom out in HEPA filter gel seal.
Using the alignment guides, raise the filter into place, ensuring
filter gel seal channel seat into knife edge of plenum.
NOTE:
Do not bottom out gel seal in plenum knife edge. The gel
seal needs to ‘float’ in gel seal to ensure proper seal.
FAN FILTER UNIT - HIGH EFFICIENCY
INSTALLATION & SERVICE INSTRUCTIONS
FILTER
MEDIA
GEL
SEAL
CONTACT
POINT
CAM
LOCK
HEPA FILTER
OUTER FRAME
KNIFE
EDGE