background image

SOFTWARE VERSION 3.6

WWW.PRG.COM

V676

®

 CONTROL CONSOLE

INSTALLATION & OPERATION MANUAL

Summary of Contents for V676

Page 1: ...SOFTWARE VERSION 3 6 WWW PRG COM V676 CONTROL CONSOLE INSTALLATION OPERATION MANUAL...

Page 2: ...eir respective companies This manual is for informational use only and is subject to change without notice Please check www prg com for the latest version PRG assumes no responsibility or liability fo...

Page 3: ...l be used only by you your employees or your authorized agents You agree to provide notice to PRG immediately after learning of or having reason to suspect a breach of any of the restrictions set fort...

Page 4: ...vance with us you cannot take us to court and you may not join your action with any other party You can address such grievances through arbitration only and you are hereby consenting to do it in Dalla...

Page 5: ...sion or any other cause beyond the control of PRG This warranty does not cover consumable parts such as fuses lamps color media or components which may be warranted directly to the Customer by the ori...

Page 6: ...s determined by PRG Refer to service manual before operating or servicing WARNING Power supply plug and or power switch circuit breaker shall remain readily operable WARNING For personal safety this e...

Page 7: ...rcuit lectrique par un lectricien qualifi pour assurer la prise est correctement mise la terre Si la prise est un standard 2 broches prise il est de votre responsabilit et l obligation de la faire rem...

Page 8: ...VI V676 CONTROL CONSOLE INSTALLATION OPERATION MANUAL Notes...

Page 9: ...MX Processing Module 4 Desk Layout 5 Console Front and Rear Panels 6 Installation Unpack and Setup Procedure 7 Display Setup 12 Using Standard DVI Monitors 12 Basic Operation About Vx76 Software 13 Po...

Page 10: ...VIII V676 CONTROL CONSOLE INSTALLATION OPERATION MANUAL Notes...

Page 11: ...cumentation For more information refer to the following PRG manuals Vx76 Software User Manual 02 9814 0001 xx PRG Lighting Systems Networking Guide 02 3004 1000 0 PRG Node Plus User Manual 02 9801 030...

Page 12: ...tton Button Front Panel button double click Button Touchscreen soft button Example Press Plan View to open plan view Button Software menu or window dialog button Example Click OK Example At Operation...

Page 13: ...st and intuitive access to 2 000 luminaires PRG Node Plus provides up to 6 additional universes PRG Super Node provides up to 16 additional universes PRG Series 400 Ethernet Switch allows 2 or more co...

Page 14: ...PRG These are optional items which do not affect the function or capabilities of the console DMX Processing Module An optional DMX Processing Module with eight 8 5 pin DMX512 Outputs one 1 5 pin DMX5...

Page 15: ...0 Clear 1 2 3 4 7 5 6 8 9 At Full Time Thru Link Loop Enter Sub Rate Grab Force Help Query Mark Cue Cue Board Dimmer Cue Stack Delay Speed Block UnBlk Track Back Track Wait Trail Store Manual Revert C...

Page 16: ...RDM 1 DMX Out 2 3 4 5 6 7 8 DMX RDM DMX RDM DMX RDM DMX RDM DMX RDM DMX RDM DMX RDM DMX RDM In Link Act Link Act C o n s o l e Trigger In Thru Out Tx Rx In In In Out Tx Rx Lk System Comm MIDI SMPTE I...

Page 17: ...AL 7 INSTALLATION Unpack and Setup Procedure Step 1 Remove all components from shipping container Figure 4 Step 2 Place console on a sturdy table or other flat surface Figure 4 Unpacking the V676 Cons...

Page 18: ...al monitors should be installed Note If DVI monitors are to be used instead of PRG provided monitors refer to Display Setup on page 12 Step 3 At rear of console install one support arm for each extern...

Page 19: ...nnectors as shown Step 6 Connect AC Power Cable supplied from AC In connector at back of console to AC power source Figure 6 Connecting Components to V676 Console Note The console supports up to two 2...

Page 20: ...g Desk Lamps INPUT POWER LABEL COMPLIENCE LABEL DMX RDM 1 DMX Out 2 3 4 5 6 7 8 DMX RDM DMX RDM DMX RDM DMX RDM DMX RDM DMX RDM DMX RDM DMX RDM In Link Act Link Act C o n s o l e Trigger In Thru Out T...

Page 21: ...Trigger In Thru Out Tx Rx In In In Out Tx Rx Lk System Comm MIDI SMPTE In Serial Data A B Displays Accessory Aux Ethernet Enable Enable 1 2 USB 100 240 VAC Line Neut Line SMPTE Input Connection Switc...

Page 22: ...g to non existent displays Refer to Figure 9 There is an LED indicator on the back of the external displays Indications are as follows Green indicates a good video signal Yellow indicates no video Usi...

Page 23: ...to power up the console and Mac computer and to launch the software application To power up and launch Step 1 At rear of console set breaker switch to ON position Refer to Figure 3 on page 6 Step 2 At...

Page 24: ...ow file will automatically load and Task Progress window will show progress of data downloads Power Down Console When the console s blue power down button is pressed a shutdown dialog will be displaye...

Page 25: ...ming and play back Operation is similar to any standard touchscreen display The console s external monitors are also touch enabled For applicable software screens the touchscreen interface may be used...

Page 26: ...MIDI In Flashes green when when a MIDI message is received Out Flashes green when a MIDI message is transmitted SMPTE SMPTE In Lights green when a valid SMPTE input signal is present Serial Data Tran...

Page 27: ...ink to another Ethernet device Activity Flashes green when an Ethernet message is received or transmitted DMX Out 1 8 DMX Lights green when DMX512 is being transmitted RDM Lights green when an RDM mes...

Page 28: ...s fader backlights c Freeze button controls desk lamps d Rate button controls external monitors e Clear button controls internal monitors front panel displays Step 2 While holding down button turn Rat...

Page 29: ...ssible Art Net sACN 16 universes DMX512 8 Universes Interfaces Copper and Fiber Optic Ethernet connections for communications protocol 8 5 pin DMX512 Outputs 1 5 pin DMX512 Input 1 Ethernet DMX Output...

Page 30: ...20 V676 CONTROL CONSOLE INSTALLATION OPERATION MANUAL Figure 11 V676 Console Dimensions 1 189 mm 46 80 620 mm 24 40 28 60 726 mm 10 90 277 mm 297 mm 11 70 11 5 292 mm 9 75 248 mm 381 mm 15 0...

Page 31: ...V676 Control Console Installation Operation Manual Version as of March 22 2013 PRG part number 02 9824 0002...

Page 32: ...Production Resource Group LLC Dallas Office 8617 Ambassador Row Suite 120 Dallas Texas 75247 www prg com...

Reviews: