SECTION 06B: ELECTRICAL
8
MID 188 PSID # 104 Driver Light Sw (A44 J1:3)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
output A44 J1:3 but
output not active
Driver Light
L16 always ON
A44 module failure
Connector C45 corroded
Circuit 39D shorted to battery
FMI 4
Shorted Low
Output A44 J1:3
shorted to ground
Driver Light
L16 not
working
A44 module failure
Connector C45 corroded
Circuit 39D shorted to ground
FMI 5
Open Circuit
A44 module does not
detect Driver Light
L16
Driver Light
L16 not
working
A44 module failure
L16 open circuit
Circuit 39D open
FMI 6
Current
above normal
Output A44 J1:3
internal software fuse
active for overcurrent
Driver Light
L16 not
working
A44 module failure
Connector C45 corroded
Circuit 39D shorted to ground
Low resistance value
MID 188 SID # 67 Driver Light Sw (A55 J1:5)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage above
normal on A55 J1:5
Driver Light not
working
A55 module failure
Sw24 failure
Circuit 39 shorted to battery
FMI 4
Shorted Low
Voltage below normal
on A55 J1:5
Driver light
always ON
A55 module failure
Sw24 failure
Circuit 39 shorted to ground
MID 188 PSID # 29 Driver Rfg Sol (A46 J1:5)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
output A46 J1:5 but
output not active
Driver’s A/C
always ON
A46 module failure
Connector C4 corroded
Connector C18 corroded
Circuit 116A shorted to battery
FMI 4
Shorted Low
Output A46 J1:5
shorted to ground
Driver’s A/C not
working
A46 module failure
Connector C4 corroded
Connector C18 corroded
Circuit 116A shorted to ground
FMI 5
Open Circuit
A46 module does not
detect Driver Liquid
Solenoid Valve So7
Driver’s A/C not
working
A46 module failure
So7 open
Circuit 116A open
FMI 6
Current
above normal
Output A46 J1:5
internal software fuse
active for overcurrent
Driver’s A/C not
working
A46 module failure
Connector C4 corroded
Connector C18 corroded
Circuit 116A shorted to ground
Solenoid Valve So7 low
resistance value (expected
value ± 40 ohms)
Summary of Contents for X3-45 2016
Page 4: ......
Page 16: ...Section 00 GENERAL INFORMATION PA1593 12 FIGURE 12 METRIC US STANDARD CONVERSION TABLE 00005...
Page 17: ...Section 00 GENERAL INFORMATION 13 PA1593 FIGURE 13 CONVERSION CHART 00006...
Page 18: ......
Page 26: ......
Page 58: ......
Page 72: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 14 7 TORQUE SPECIFICATIONS...
Page 73: ...SECTION 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 15...
Page 74: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 16...
Page 76: ......
Page 96: ......
Page 134: ......
Page 176: ...SECTION 06B ELECTRICAL 38 overcurrent working Circuit 306 shorted to ground...
Page 180: ......
Page 202: ......
Page 205: ...Section 09 PROPELLER SHAFT PA1593 3 FIGURE 1 PROPELLER SHAFT ASSEMBLY 09002...
Page 256: ......
Page 268: ......
Page 295: ...SECTION 16 SUSPENSION PA1593 9 2 5 TORQUE SPECIFICATIONS...
Page 296: ...Section 16 SUSPENSION PA1593 10...
Page 297: ...Section 16 SUSPENSION PA1593 11...
Page 314: ......
Page 380: ......
Page 388: ......
Page 413: ...Section 22 HEATING AND AIR CONDITIONING PA1593 15 FIGURE 18 REFRIGERANT CIRCUIT CENTRAL SYSTEM...
Page 433: ...Section 22 HEATING AND AIR CONDITIONING PA1593 35 FIGURE 36 CENTRAL HEATING SYSTEM COMPONENTS...