SECTION 06B: ELECTRICAL
29
output not active
Valve So11
always ON
failure
Connector C9, C15 or C58
corroded
Circuit 77C or 77B shorted to
battery
FMI 4
Shorted Low
Output A54 J1:3
shorted to ground
Pass Liquid
Solenoid
Valve So11
not working
A54 module failure
Pass Liquid Solenoid Valve So11
failure
Connector C9, C15 or C58
corroded
Circuit 77C or 77B shorted to
ground
FMI 5
Open Circuit
A54 module does not
detect Pass Liquid
Solenoid Valve So11
Pass Liquid
Solenoid
Valve So11
not working
A54 module failure
Pass Liquid Solenoid Valve So11
open circuit
Circuit 77C or 77B open
FMI 6
Current
above normal
Output A54 J1:3
internal software fuse
active for overcurrent
Pass Liquid
Solenoid
Valve So11
not working
A54 module failure
Connector C9, C15 or C58
corroded
Circuit 77C or 77B shorted to
ground
MID 188 PSID # 17 Pass Wtr pump (A54 J1:4)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
output A54 J1:4 but
output not active
Pass Water
pump always
ON
A54 module failure
Water pump relay R20 failure
Connector C9 corroded
Circuit 57G shorted to battery
FMI 4
Shorted Low
Output A54 J1:4
shorted to ground
Pass Water
pump not
working
A54 module failure
Water pump relay R20 failure
Connector C9 corroded
Circuit 57G shorted to ground
FMI 6
Current
above normal
Output A54 J1:4
internal software fuse
active for overcurrent
Pass Water
pump not
working
A54 module failure
Connector C9 corroded
Circuit 57G shorted to ground
Water pump relay R20 shorted to
ground
MID 188 SID # 68 Read Light Tst (A42 J1:19)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
input A42 J1:19 but
switch Sw5 not active
Reading
Lights not
working
A42 module failure
Reading Lamp Test switch Sw5
failure
Connector C72 corroded
FMI 4
Shorted Low
Input A42 J1:19
shorted to ground
Reading
Lights always
ON
A42 module failure
Reading Lamp Test switch Sw5
failure
Connector C72 corroded
Wire between A42 J1:19 and
Sw5 pin 3 shorted to ground
Summary of Contents for X3-45 2016
Page 4: ......
Page 16: ...Section 00 GENERAL INFORMATION PA1593 12 FIGURE 12 METRIC US STANDARD CONVERSION TABLE 00005...
Page 17: ...Section 00 GENERAL INFORMATION 13 PA1593 FIGURE 13 CONVERSION CHART 00006...
Page 18: ......
Page 26: ......
Page 58: ......
Page 72: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 14 7 TORQUE SPECIFICATIONS...
Page 73: ...SECTION 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 15...
Page 74: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 16...
Page 76: ......
Page 96: ......
Page 134: ......
Page 176: ...SECTION 06B ELECTRICAL 38 overcurrent working Circuit 306 shorted to ground...
Page 180: ......
Page 202: ......
Page 205: ...Section 09 PROPELLER SHAFT PA1593 3 FIGURE 1 PROPELLER SHAFT ASSEMBLY 09002...
Page 256: ......
Page 268: ......
Page 295: ...SECTION 16 SUSPENSION PA1593 9 2 5 TORQUE SPECIFICATIONS...
Page 296: ...Section 16 SUSPENSION PA1593 10...
Page 297: ...Section 16 SUSPENSION PA1593 11...
Page 314: ......
Page 380: ......
Page 388: ......
Page 413: ...Section 22 HEATING AND AIR CONDITIONING PA1593 15 FIGURE 18 REFRIGERANT CIRCUIT CENTRAL SYSTEM...
Page 433: ...Section 22 HEATING AND AIR CONDITIONING PA1593 35 FIGURE 36 CENTRAL HEATING SYSTEM COMPONENTS...