TECHNICAL INFORMATION
5 - 16
Main
Code
Sub
Code
Description
Do Not
Shift
Light
Inhibited Operation Description
42
25
Short to battery, K solenoid circuit
No
K solenoid operation inhibited
42
26
Short to battery, N solenoid circuit
No
Low and 1st inhibited
43
21
Low side driver, F solenoid circuit
No
Lock-up inhibited
43
25
Low side driver, K solenoid circuit
No
K solenoid operation inhibited
43
26
Low side driver, N solenoid circuit
No
Low and 1st inhibited
44
12
Short to ground, A solenoid circuit
Yes
DNS, SOL OFF (Hydraulic default)
44
13
Short to ground, B solenoid circuit
Yes
DNS, SOL OFF (Hydraulic default)
44
14
Short to ground, C solenoid circuit
Yes
DNS, SOL OFF (Hydraulic default)
44
15
Short to ground, D solenoid circuit
Yes
DNS, SOL OFF (Hydraulic default)
44
16
Short to ground, E solenoid circuit
Yes
DNS, SOL OFF (Hydraulic default)
44
21
Short to ground, F solenoid circuit
No
Lock-up inhibited
44
22
Short to ground, solenoid circuit
Yes
DNS, SOL OFF (Hydraulic default)
44
23
Short to ground, H solenoid circuit
No
Retarder allowed. differential lock
inhibited
44
24
Short to ground, J solenoid circuit
No
Low and 1st inhibited
44
25
Short to ground, K solenoid circuit
No
K solenoid operation inhibited
44
26
Short to ground, N solenoid circuit
No
Low and 1st inhibited
45
12
Open circuit, A solenoid circuit
Yes
DNS, SOL OFF (Hydraulic default)
45
13
Open circuit, B solenoid circuit
Yes
DNS, SOL OFF (Hydraulic default)
45
14
Open circuit, C solenoid circuit
Yes
DNS, SOL OFF (Hydraulic default)
45
15
Open circuit, D solenoid circuit
Yes
DNS, SOL OFF (Hydraulic default)
45
16
Open circuit, E solenoid circuit
Yes
DNS, SOL OFF (Hydraulic default)
45
21
Open circuit, F solenoid circuit
No
Lock-up inhibited
45
22
Open circuit, G solenoid circuit
Yes
DNS, SOL OFF (Hydraulic default)
45
23
Open circuit, H solenoid circuit
No
Retarder allowed differential lock
inhibited
45
24
Open circuit, J solenoid circuit
No
Low and 1st inhibited
45
25
Open circuit, K solenoid circuit
No
K solenoid operation inhibited
45
26
Open circuit, N solenoid circuit
No
Low and 1st inhibited
51
10
Offgoing ratio test (during shift), 1 to L
Yes
Low and 1st inhibited
51
12
Offgoing ratio test (during shift), 1 to 2
Yes
DNS, RPR
51
21
Offgoing ratio test (during shift), 2 to 1
Yes
DNS, RPR
51
23
Offgoing ratio test (during shift), 2 to 3
Yes
DNS, RPR
51
43
Offgoing ratio test (during shift), 4 to 3
Yes
DNS, RPR
51
45
Offgoing ratio test (during shift), 4 to 5
Yes
DNS, RPR
51
65
Offgoing ratio test (during shift), 6 to 5
Yes
DNS, RPR
52
01
Offgoing C3PS test (during shift), L to 1
Yes
DNS, RPR
52
08
Offgoing C3PS test (during shift), L to N1
Yes
DNS, NNC