TECHNICAL INFORMATION
5 - 14
Diagnostic Code List and Description
Main
Code
Sub
Code
Description
Do Not
Shift
Light
Inhibited Operation Description
12
12
Oil level, low
No
No upshift above a calibration range
12
23
Oil level, high
No
No upshift above a calibration range
13
12
ECU input voltage, low
Yes
DNS, SOL OFF (Hydraulic default)
13
13
ECU input voltage, medium low
No
None: Shift adaptive feature will not
function.
13
23
ECU input voltage, high
Yes
DNS, SOL OFF (Hydraulic default)
14
12
Oil level sensor, low
No
None
14
23
Oil level sensor, high
No
None
21
12
Throttle position sensor, low
No
Use Throttle default value
21
23
Throttle position sensor, high
No
Use Throttle default value
22
14
Engine speed sensor reasonableness test
No
Use default engine speed
22
15
Turbine speed sensor reasonableness test
Yes
DNS, Lock in current range
22
16
Output speed sensor reasonableness or
rapid decel test
Yes
DNS, Lock in current range
23
12
Primary Shifter or RSI Link Fault
No
Hold in last valid direction
23
13
Primary Shifter Mode Function Fault
No
Mode change not permitted
23
14
Secondary Shifter or RSI Link Fault
No
Hold in last valid direction
23
15
Secondary Shifter Mode Function Fault
No
Mode change not permitted
24
12
Sump oil temperature, cold
Yes
DNS
24
23
Sump oil temperature, hot
No
No upshifts above a calibration range
25
00
Output speed reasonableness test, detected
at 0 speed, (L)
Yes
DNS, Lock in current range (L)
25
11
Output speed reasonableness test, detected
at 0 speed, (1st)
Yes
DNS, Lock in current range (1st)
25
22
Output speed reasonableness test, detected
at 0 speed 2nd
Yes
DNS, Lock in current range (2nd)
25
33
Output speed reasonableness test, detected
at 0 speed, 3rd
Yes
DNS, Lock in current range (3rd)
25
44
Output speed reasonableness test, detected
at 0 speed, 4th
Yes
DNS, Lock in current range (4th)
25
55
Output speed reasonableness test, detected
at 0 speed, 5th
Yes
DNS, Lock in current range (5th)
25
66
Output speed reasonableness test, detected
at 0 speed, 6th
Yes
DNS, Lock in current range (6th)
25
77
Output speed reasonableness test, detected
at 0 speed, R
Yes
DNS, Lock in current range (R)
32
00
C3 pressure switch open, L range
Yes
DNS, Lock in current range (L)