9
III. Hand Unit 3
. Detailed Description
A. Grip Configurations
.
1. The Hand Unit can be set-up with a molded Hand Grip for Focus and Iris control or with
the Hand Grip replaced by a flat cover to accommodate a bracket and Micro Force zoom
control.
2. Removing the Hand Grip. The Handgrip is removed to allow the bracket for the Micro
Force to be installed.
Press the Grip Release toward the HU3 housing (1).
Slide the Grip downward (2)
Replace the Grip with the cover (3).
Install the Micro Force bracket using the threaded hole at the rear of the
HU3.
HU3 with Hand Grip
and Quick Release Plate
HU3 with Micro Force
and bracket 4336
(1)
(2)
(3)