![Pressol Pneumatic Oilpump 3:1 Operating Instructions Manual Download Page 6](http://html1.mh-extra.com/html/pressol/pneumatic-oilpump-3-1/pneumatic-oilpump-3-1_operating-instructions-manual_1598031006.webp)
Pneumatic Oil Pump 3:1
Operating Instructions
3.2
Wall Mounting
Note
When installing the 3:1 oil pump in connection with long distribution lines we recommend the use
of a foot valve
To avoid possible overpressures in the pump we recommend in any case the installation of a foot
valve with an overpressure releasing drill hole (art.no. 03337).
•
For fixation of the oil pump we require 2 screws with a diameter of 10 or 12 mm (not included in
the product packageChoose screws corresponding to the wall material, on which the pump
shall be mounted.
•
Take care for a stabil wall mounting of the pump. Take care for a protected mounting location,
protecting i.e. against splash water,
•
Please mount the calibratable pump for a trouble-free operation of the integral air elimator in an
upright position, only.
•
Fix suction tube using the G 2“ drum retention adapter on the container or on the storage tank.
•
Connect suction tube and pump with suction hose (hose connection G ¾“)
•
The air- and oil back-flow tube of the calibratable pump version shall be lead back into the
container or tank utilizing the drilled hole in the drum adapter.
•
Connect oil pump with control valve or manual flow meter and oil discharge pipe work with a
discharge hose.
•
Installation material for discharge pipe work
•
Length of discharge pipe work up to 15 m: Pipe work tube DN 20 (R ¾“) DIN 2448 or
bigger; St 37 acc. to DIN 1629.
•
Length of discharge pipe work exceeding 15 m: Pipe work tube DN 32 (R 1 ¼“) DIN 2448
or bigger; St 37 acc. to DIN 1629.
•
Overflow valve (see accessories).
•
Lever ball valve (see accessories).
Note
Pay attention to a correct installation ad to a accurate connection of the accessories with the
pump
Use suitable sealing material in any case. (i.e. Teflon-tape).
•
The pump is now ready for operation.
6
Status 31.01.2008