![Pressol Pneumatic Oilpump 3:1 Operating Instructions Manual Download Page 23](http://html1.mh-extra.com/html/pressol/pneumatic-oilpump-3-1/pneumatic-oilpump-3-1_operating-instructions-manual_1598031023.webp)
Operating instructions
Oil hose end meter
2.2
Discription of the to be applied safety instructions
The safety instructions included in these operating instructions are linked to the
following hazard rating. This hazard rating is indicated in the instructions with the
following keyword and pictogram:
Pictogram Keyword Consequences
if
the safety instructions are not
complied with
Attention
Potentially light to moderate physical injury or
material damage
Table 2-1: Classification of the safety instructions according to type and severity of the hazard
In addition, further instructions are provided which give general tips on handling the
product.
Pictogram Keyword Meaning
Instruction
Background knowledge or tips on how to handle the
product correctly
Table 2-2: General instruction
2.2
Safety instructions on hazards relating to handling the hand-held
volume flow meter
Attention!
The hose end meter is suitable only for use with media of low flammability.
The hose end meter must not be used in explosion hazard areas.
Instruction
§ 19g WHG is particularly important. It prescribes that filling equipment must be
acquired, installed, set up, maintained, and operated in such a way that contamination
of water bodies or any other lasting modification of their properties is avoided.
Under § 19i WHG, the operator of such equipment is obliged to permanently monitor
his equipment so that the above-mentioned requirements are complied with at the
filling location.
3.
Installation
•
The meter is supplied ready mounted.
•
Depending on the model, accessories may or must be fitted.
Information
When fitting, ensure cleanliness and an exact connection and sealing (copper seal or
Teflon tape) with the oil pressure hose.
4