Operating Instructions
Pneumatic Oil Pump 3:1
2.2
Risks when Working with the Oil Pump
Warning!
Never work on a pump that is running!
Mount or remove attachments and accessories only when the pump is switched off.
Warning!
Do not pump contaminated fluids!
Take special care to ensure that there is no contaminant in the fluid to be pumped.
Install a strainer on the suction pipe.
Warning!
Damaged attachments and accessories can lead to personal injury and material damage!
Suction and pressure pipes must not be kinked, twisted or stretched.
The pressure-side installation of an overflow valve is recommended (see accessories).
Attachments and accessories must be checked for wear, splits or other damage at all times.
Damaged attachments and accessories must be replaced immediately.
With reference to the period of use, please note the details in ZH 1/A45.4.2 or DIN 20066
Part 5.3.2.
Caution!
Spilled fuel can result in environmental damage
Local and country rules and regulations relating to domestic water supplies and fuel storage
must be obeyed
.
3. Assembly
•
The oilpump can be used for oil supply out of original drums or out of oil storage tanks.
Note
An upward installation of the suction line is recommended according to European regulation.
Consider before assembly the height of the container used and in case of necessity the use of an
oil container storage unit..
3.1
Barrel- and Tank Mounting
•
Fix pump and suction tube using the G 2“ drum retention adapter on the container or on the
storage tank.
•
Connect the discharge hose to the pump connecting adapter G ½“.
•
Connect the discharge valve or the manual flow meter to the discharge hose.
Status 31.01.2008
5