Pressol mobiFITT Operating Instructions And Safety Notes Download Page 5

5

Operating Instructions - mobiMASTER and mobiFITT  

GB

 

2.    Safety notes 

Various dangers may occur if the mobiMASTER and the mobiFITT are improperly handled during instal-

lation, commissioning and daily operation.

WARNING

Risk of injury and damage to material property because of improper handling!

Hold the instructions at the disposal of the operating staff at the usage site 

of the unit.

Country-specific safety measures and accident prevention regulations must 

be observed.

2.1   Authorized personnel 

Only qualified and authorized persons are allowed to operate and to work on the mobiMASTER and 

mobiFITT. 
Persons are qualified if they are, due to their training, experience, instruction and knowledge of the 

relevant standards, able to assess assigned tasks and to identify potentially hazardous situations.  
All persons charged with installation, operation, maintenance and repair work, must have read and 
understood this operation manual. 

2.2   Intended conditions of use 

The mobiMASTER and the mobiFITT are mobile tanks and have been exclusively designed for the delivery 

of and the refuelling with heating oil or diesel fuel.
The mobiMASTER with an internal volume of 450 l is available with a diesel pump with a 12 V DC or a  

24 V DC motor.
The mobiFITT is available in two sizes, with an internal volume of 200 l or 300 l, and with a diesel pump 

with a 12 V DC motor.

ATTENTION

Danger of product damage

No other fluid types than diesel and heating oil are allowed to be stored in this 

product.

Any application or modification beyond the intended use can lead to hazardous situations and shall be 

regarded as non-intended use.
The user is liable for any damage resulting from non-intended use.

2.3   Notes on maintenance, cleaning and repair 

WARNING 

Risk of injury and damage to material property because of improper 

maintenance and repair

Should unusual noises occur, immediately stop the diesel pump. Immediately 

identify and eliminate the cause in order to avoid consequential damages.

Observe the safety sheet for diesel fuels and heating oils.

3.    Area of application 

The mobiMASTER and the mobiFITT are mobile tanks and are suited for the transport of and for refuel-

ling with heating oil and diesel fuels.

Summary of Contents for mobiFITT

Page 1: ...89 832 932 A401GB OPERATING INSTRUCTIONS AND SAFETY NOTES mobiMASTER and mobiFITT 230 V 12 V DC 24 V DC...

Page 2: ...8 1 Equipment __________________________________________________________________________9 9 Operation__________________________________________________________________________11 10 Installed component...

Page 3: ...necessary information The obligations of the personal are specified in the ADR provisions Please observe the following instructions in the interest of all concerned Refrain from any unsafe working met...

Page 4: ...or tips which facilitate work 1 3 2 Hazard symbols Symbol Meaning General hazard symbol The warning note marked in this way contains supple mentary information on the type of hazard This symbol warns...

Page 5: ...mobile tanks and have been exclusively designed for the delivery of and the refuelling with heating oil or diesel fuel The mobiMASTER with an internal volume of 450 l is available with a diesel pump w...

Page 6: ...d up hoses and lines and locked cover The filled tank is only allowed to be loaded and unloaded by means of a stacker or a crane whereby the load carriers must be correctly fixed In transport vehicles...

Page 7: ...and lamp ATTENTION Escape of fluid The mobiMASTER or mobiFITT tanks must not be damaged during transport or storage The tank s equipment is to be maintained in a usable condition at all times 6 Traini...

Page 8: ...ign vane pump selfpriming Delivery rate under free discharge up to l min 56 35 54 35 54 Discharge pressure up to bar 1 8 1 6 1 8 1 6 1 6 Pumping media heating oil and diesel fuels Temperature range pu...

Page 9: ...re range pumping media C 10 60 Connecting cable length m 3 3 3 Motor data pump Voltage V 12 DC 24 DC 12 DC 24 DC 12 DC 24 DC Power consumption A 13 19 13 19 13 19 Thermal protection self resetting Fus...

Page 10: ...pment 1 Separating wall 2 Suction hose 3 Foot valve 4 Lockable protection cover 5 Airing and venting valve 6 Discharge hose 7 Level indicator 8 Built in meter digital 9 Filler neck 10 Diesel pump 11 A...

Page 11: ...commissioning and use and they are to be complied with a chapter 10 installed components Filling and discharging may take place only under the supervision of an authorised employee No damage to the fu...

Page 12: ...e outside the guarantee period then the service costs will be charged to the owner Standard maintenance of systems e g filter cleaning battery replacement calibration of the flow meter is excluded fro...

Page 13: ...sult the tank is to be repaired by an authorised manufacturer The following minimum information must exist for each fuel tank Manufacturer s designation Name of the current owner Serial number of the...

Page 14: ...00 Plze Czech Republic 87 100 Toru Polska Street and house number Nepomuck 1729 3 ul P aska 64 Contact person Phone number Table 1 Control report for tank manufacturer Code 31H2 Z Serial number Name o...

Page 15: ...15 Operating Instructions mobiMASTER and mobiFITT GB 17 Damage and repair report Date signature Errors and actions taken Table 3 Damage and repair report...

Page 16: ...16 GB Operating Instructions mobiMASTER and mobiFITT 18 Exploded view mobiMASTER Fig 18 1 Exploded view mobiMASTER...

Page 17: ...g G 1 fem G 1 fem 23 225 950 15 1 Lever lock 89 835 16 6 O ring NBR 70 5x1 5 01 371 17 4 Washer punched steel 00 432 007 18 1 Sealing ring 89 279 19 1 Threaded fitting M 5x4 89 278 20 4 Cylinder head...

Page 18: ...18 GB Operating Instructions mobiMASTER and mobiFITT Fig 19 1 Exploded view mobiFITT 19 Exploded view mobiFITT...

Page 19: ...85 392 16 2 Washer punched steel 00 432 007 17 2 Cylinder head screw M 8x10 88 025 18 6 Screw M 5x20 89 825 19 4 Screw 3 9x9 5 87 929 20 1 O ring for tank lock 81 317 21 1 Neck for filler cap 81 316 2...

Page 20: ...ort and refuelling with heating oil and diesel fuels Year of manufacture see type plate Serial number Complies with all relevant provisions of the following directives EC Directives 2006 42 EC Machine...

Page 21: ...elling with heating oil and diesel fuels Year of manufacture see type plate Serial number Complies with all relevant provisions of the following directives EC Directives 2006 42 EC Machinery Directive...

Page 22: ...22 GB Operating Instructions mobiMASTER and mobiFITT...

Page 23: ...23 Operating Instructions mobiMASTER and mobiFITT GB...

Page 24: ...Pressol Schmierger te GmbH Parkstra e 7 93167 Falkenstein Germany Tel 49 9462 17 0 Fax 49 9462 17 208 info pressol com www pressol com...

Reviews: