Pressol mobiFITT Operating Instructions And Safety Notes Download Page 19

19

Operating Instructions - mobiMASTER and mobiFITT  

GB

 

Pos.

Quantity Designation

Item no.

1

4

Nut M6

00 044

2

8

Hexagon head screw  M 6x16

89 481

3

12

Flat washer DIN 9021

87 126

4

4

NBR-vibration damper

83 019

5

1

MOBIFIxx diesel pump 35 l/min - for mobiFITT

23 404 964

6

1

Adapter G 1" male-G 1" male

85 358

7

1

Positioning fitting-G 1“ fem-G 1“ fem

23 225

8

1

Adapter G1" fem - G1" male

81 486

9

1

Swivel joint  DN 19

19 625

10

2

Bend 90°-Al-DN 19

85 370 777

11

1

NUMERIxx³-G 1" fem-G 1" fem

23 190 091

12

6

O-ring-NBR 70-29x2,5

89 111

13

2

Positioning fitting-Al-G 1" male-G 1" fem NW25

23 218

14

1

Pump foot for mobiFITT

87 238

15

1

Bend

85 392

16

2

Washer punched steel

00 432 007

17

2

Cylinder head screw M 8x10

88 025

18

6

Screw M 5x20

89 825

19

4

Screw 3,9x9,5

87 929

20

1

O-ring for tank lock

81 317

21

1

Neck for filler cap

81 316

22

1

Tank lock for mobiFITT

89 822

23

1

Suction hose for diesel

23 155 967

24

1

Automatic nozzle valve diesel

23 176 777

25

1

Swivel joint  DN 19

19 621

26

1

Angled tap 90°

19 779

27

1

Special adapter AlSi12

89 811

28

1

Discharge hose for diesel, G 1" male, G 1" male, DN 19

82 605

29

1

Suction strainer G 1“ male

23 180

30

1

Check valve

19 892

31

1

Washer DIN522 A

02 853

32

1

Cylinder head screw M 5x10

89 443

33

1

Lever lock

89 835

34

1

Airing and venting valve

45 140

35

1

Spiral-level indicator mechanical

82 602

36

1

mobiFITT-300 l tank

45 482 155

37

6

O-ring-NBR 70-5x1,5

01 371

Tab. 19-1: Overview of components for fig. 19-1

Summary of Contents for mobiFITT

Page 1: ...89 832 932 A401GB OPERATING INSTRUCTIONS AND SAFETY NOTES mobiMASTER and mobiFITT 230 V 12 V DC 24 V DC...

Page 2: ...8 1 Equipment __________________________________________________________________________9 9 Operation__________________________________________________________________________11 10 Installed component...

Page 3: ...necessary information The obligations of the personal are specified in the ADR provisions Please observe the following instructions in the interest of all concerned Refrain from any unsafe working met...

Page 4: ...or tips which facilitate work 1 3 2 Hazard symbols Symbol Meaning General hazard symbol The warning note marked in this way contains supple mentary information on the type of hazard This symbol warns...

Page 5: ...mobile tanks and have been exclusively designed for the delivery of and the refuelling with heating oil or diesel fuel The mobiMASTER with an internal volume of 450 l is available with a diesel pump w...

Page 6: ...d up hoses and lines and locked cover The filled tank is only allowed to be loaded and unloaded by means of a stacker or a crane whereby the load carriers must be correctly fixed In transport vehicles...

Page 7: ...and lamp ATTENTION Escape of fluid The mobiMASTER or mobiFITT tanks must not be damaged during transport or storage The tank s equipment is to be maintained in a usable condition at all times 6 Traini...

Page 8: ...ign vane pump selfpriming Delivery rate under free discharge up to l min 56 35 54 35 54 Discharge pressure up to bar 1 8 1 6 1 8 1 6 1 6 Pumping media heating oil and diesel fuels Temperature range pu...

Page 9: ...re range pumping media C 10 60 Connecting cable length m 3 3 3 Motor data pump Voltage V 12 DC 24 DC 12 DC 24 DC 12 DC 24 DC Power consumption A 13 19 13 19 13 19 Thermal protection self resetting Fus...

Page 10: ...pment 1 Separating wall 2 Suction hose 3 Foot valve 4 Lockable protection cover 5 Airing and venting valve 6 Discharge hose 7 Level indicator 8 Built in meter digital 9 Filler neck 10 Diesel pump 11 A...

Page 11: ...commissioning and use and they are to be complied with a chapter 10 installed components Filling and discharging may take place only under the supervision of an authorised employee No damage to the fu...

Page 12: ...e outside the guarantee period then the service costs will be charged to the owner Standard maintenance of systems e g filter cleaning battery replacement calibration of the flow meter is excluded fro...

Page 13: ...sult the tank is to be repaired by an authorised manufacturer The following minimum information must exist for each fuel tank Manufacturer s designation Name of the current owner Serial number of the...

Page 14: ...00 Plze Czech Republic 87 100 Toru Polska Street and house number Nepomuck 1729 3 ul P aska 64 Contact person Phone number Table 1 Control report for tank manufacturer Code 31H2 Z Serial number Name o...

Page 15: ...15 Operating Instructions mobiMASTER and mobiFITT GB 17 Damage and repair report Date signature Errors and actions taken Table 3 Damage and repair report...

Page 16: ...16 GB Operating Instructions mobiMASTER and mobiFITT 18 Exploded view mobiMASTER Fig 18 1 Exploded view mobiMASTER...

Page 17: ...g G 1 fem G 1 fem 23 225 950 15 1 Lever lock 89 835 16 6 O ring NBR 70 5x1 5 01 371 17 4 Washer punched steel 00 432 007 18 1 Sealing ring 89 279 19 1 Threaded fitting M 5x4 89 278 20 4 Cylinder head...

Page 18: ...18 GB Operating Instructions mobiMASTER and mobiFITT Fig 19 1 Exploded view mobiFITT 19 Exploded view mobiFITT...

Page 19: ...85 392 16 2 Washer punched steel 00 432 007 17 2 Cylinder head screw M 8x10 88 025 18 6 Screw M 5x20 89 825 19 4 Screw 3 9x9 5 87 929 20 1 O ring for tank lock 81 317 21 1 Neck for filler cap 81 316 2...

Page 20: ...ort and refuelling with heating oil and diesel fuels Year of manufacture see type plate Serial number Complies with all relevant provisions of the following directives EC Directives 2006 42 EC Machine...

Page 21: ...elling with heating oil and diesel fuels Year of manufacture see type plate Serial number Complies with all relevant provisions of the following directives EC Directives 2006 42 EC Machinery Directive...

Page 22: ...22 GB Operating Instructions mobiMASTER and mobiFITT...

Page 23: ...23 Operating Instructions mobiMASTER and mobiFITT GB...

Page 24: ...Pressol Schmierger te GmbH Parkstra e 7 93167 Falkenstein Germany Tel 49 9462 17 0 Fax 49 9462 17 208 info pressol com www pressol com...

Reviews: