![Pressol mobiFITT Operating Instructions And Safety Notes Download Page 12](http://html1.mh-extra.com/html/pressol/mobifitt/mobifitt_operating-instructions-and-safety-notes_1598029012.webp)
12
GB
Operating Instructions - mobiMASTER and mobiFITT
ATTENTION
Damage to the product
■
■
This product is only allowed to be operated with sufficient liquid in the tank.
Otherwise, irreparable damage of the refuelling system and its premature
failure may occur!
10. Installed components
The operating instruction manual for the integrated diesel pump is added separately.
For variants with a meter, you will additionally receive the manual for the meter.
11. Guarantee
The manufacturer provides a guarantee of 5 years on the tank and of 2 years on the installed components
from the date of purchase.
If a problem should occur despite all quality measures taken, please get in touch with our
service contact partners:
PRESSOL Schmiergeräte GmbH
Tel +49 9462 17-216
Fax +49 9462 1063
[email protected]
If it should be the case that the defect arose during the guarantee period because of incorrect handling
or installation of the product, or that the defect arose outside the guarantee period, then the service costs
will be charged to the owner.
Standard maintenance of systems, e.g. filter cleaning, battery replacement, calibration of the flow meter, is
excluded from the guarantee.
The guarantee is annulled through:
– Damage resulting from incorrect installation and handling of the system
– Maintenance which was neglected, mechanical damage, or vandalism
– Defects which arise from repairs or constructional modifications carried out by an unauthorised service
provider
– Change of the purpose of the product
Pressol Schmiergeräte GmbH is not liable for damage arising from incorrect use nor contraventions
to the operating instructions or regulations.
12. Maintenance
Regular maintenance helps to reduce the risk of product failure and premature component failure.
■
■
In order to prevent the risk of leakages and spills, check to ensure that the suction and refuelling hoses
are firmly fastened.
■
■
Check the state of the power supply cables.
NOTE
■
■
Visually inspect the tank on a regular basis.
■
■
If a leakage of the tank has been detected, the fluid must be pumped into
another container.
■
■
The supplier of the device must be informed.