Alarm Cards
1-19
Alarm Cards
Alarm Card User Screens and Settings
Table 1-8. ALR 28+14 Voice Option Settings and Defaults
STATE
The State setting determines whether the port is active or inactive. An inactive port does not
occupy a time slot on a WAN link. Set the State setting to stdby (standby) for ports you are
not using or have not yet configured. Set it to actv (active) for ports that are ready for use. The
default value is stdby.
WAN/SRV
The WAN setting identifies the WAN link assigned to this port. The default value is none.
TS
The TS setting identifies the time slot on the WAN link to which this port is assigned. Values
range from 1 to 24 for T1 links and 1 to 31 for E1 links. Time slot 16 is not available on E1
links that are programmed for cas or ccs signaling. For a display of the available time slots,
refer to your cross-connect map for the WAN link. The default value is n/a. See Chapter 4,
System Configuration and Operation for more information regarding cross-connect maps.
MODE
The Mode setting should be determined by the type of equipment to which you are connecting
the port. All options use two-wire balanced connections. The fxs (Foreign Exchange - Station)
option allows you to connect a telephone to the system.
The plar (private line automatic ringdown) option provides point-to-point unswitched
connections between two telephone sets. This configuration is usually not attached to an
exchange or switch; rather, it provides a “hot line” between two locations.
Parameter
User Options
Default
STATE
stdby actv
stdby
WAN/SRV
none w1-1 through w4-2
none
TS
1 to 24 1 to 31
n/a
MODE
fxs plar
fxs
TYPE
loop d3-m1 d4-m1 d3-m2 d4-m2 d3-m3
d4-m3
loop
RX tlp
-10.0 to +2.0
-5.0
TX tlp
-10.0 to +5.0
2.0
coding
u-law a-inv a-law
u-law
ringbk
off on
off
Summary of Contents for ALR 28+14
Page 1: ...Alarm Cards Reference Guide Publication 999 001967 Revision A1 Release 3 9 October 1999 ...
Page 4: ...Model No Running Head ...
Page 6: ...ii Alarm Cards Model No Running Head Contents ...
Page 8: ...iv Alarm Cards Model No Running Head Figures ...
Page 10: ...vi Alarm Cards Model No Running Head Tables ...
Page 34: ...1 24 Alarm Cards Model No Running Head Alarm Card Troubleshooting Alarm Cards ...