background image

8

22:00

02:00

12:00

13)  Light sensor 

adjustment wheel

Open

Close

14)  Connecting terminals  

for external buttons

2 .2 .2 Activating automatic mode

To activate the automatic mode, press the Up key when the door is open or the Down key when 

the door is closed. Automatic mode is indicated by a small empty circle at the top side of the 

display. 

2 .2 .3 Deactivating the timer

If you want to operate the automatic mode with the light sensor only (see section E 2.3), then you 

can deactivate the timer by pressing the menu and OK button at the same time. The display will 

show ‘t-off’. Repeat this process if you want to reactivate the timer.  

The display will then show the current time.

2 .3 Using the light sensor

To make automatic opening and closing dependent on ambient light, connect the supplied light sensor to the device and position the sensor in a suitable 

place. Ensure that the sensor is easily able to detect daylight. The sensor must not be influenced by other sources of light (e.g. artificial light from a street 

lamp or from a house window). Do not position the sensor on roadways where light from the headlights of passing cars may influence the sensor. Please note 

that approx. one minute may elapse before the light sensor responds to a change in brightness. This prevents accidental opening of the door in the event of 

lightning. 

If automatic mode is activated, the door is opened and closed when the 

preset brightness level is reached. The opening and closing times of the 

timer (see section E 2.2) remain active even when using the light sensor. 

The following applies:

•  If the set closing time is reached, the door is always closed  

even if the light sensor still detects sufficient brightness. 

•  If the set opening time is reached, the door will remain closed until the 

light sensor has detected sufficient brightness. 

You can adjust the sensor‘s switching threshold using the adjustment 

wheel in the device. The further you turn the adjustment wheel to the 

left, the later in the morning or earlier in the evening the door closes. 

2 .4 Manual operation

Use the Up and Down buttons to open and close the door manually.  

Important:

 As soon as a manual operation is initiated, the device is in manual mode. Automatic 

operations are then no longer carried out. 

Manual mode is indicated in the display by a solid square dot on the underside.

Automatic mode can be re-initialised by pressing the Up button again while the door  

is open or the Down button while the door is closed. Automatic mode is indicated in  

the display by a small empty circle at the top.

2 .5 Switching the device off

To switch off the device, disconnect the connecting cable from the socket  

and remove the batteries.

Summary of Contents for 540257

Page 1: ...Automatic Poultry Door Puerta autom tica para gallineros EN Operating instructions ES Indstrucciones de uso 70550 US PR 540257 P1S Premier1Supplies com...

Page 2: ...2...

Page 3: ...al data 9 4 Accessories replacement articles 9 ES Instrucciones de uso 10 A Informaci n sobre el documento 10 B Informaci n sobre el producto 10 C Instrucciones de seguridad importantes 10 D Instrucci...

Page 4: ...the door is used near children Do not come in contact moving parts Only use attachments recommended or sold by the manufacturer especially the doorplates for automatic chicken door Do not use outdoors...

Page 5: ...the door to the device Measure the opening of the chicken door and provide a suitable door with guide rails Get all of the components ready You will find suitable sliders and additional pulleys in ou...

Page 6: ...bricate the sliding surfaces The pull cord must be routed unhindered from the door to the device without contacting foreign bodies The guide rails of the door are precision installed so that the door...

Page 7: ...ribed below 2 Operation 2 1 Time setting To set the current date and time press the OK button for 3 4 seconds The current set year starts to flash Change the value using the arrow buttons and confirm...

Page 8: ...a change in brightness This prevents accidental opening of the door in the event of lightning If automatic mode is activated the door is opened and closed when the preset brightness level is reached...

Page 9: ...or weekends The correct times must be set in the menu for both week days and weekends F USER MAINTENANCE INSTRUCTIONS 1 Cleaning maintenance Danger Risk of physical injury and material damage if used...

Page 10: ...a de ni os No entre en contacto con piezas m viles Utilice nicamente accesorios recomendados o vendidos por el fabricante en particular las chapas para la puerta autom tica para gallineros No lo utili...

Page 11: ...poleas adicionales en nuestra gama de accesorios a este respecto consulte el apartado 12 Si quiere que la puerta autom tica para gallineros disponga de alimentaci n por red el ctrica aseg rese de que...

Page 12: ...una manera fiable la distancia desde la corredera hasta la pared de la edificaci n no es superior a 5 mm a lo largo de todo el tramo que recorre la corredera mientras se abre Cuando se cierra la corre...

Page 13: ...esarios tal y como se describe m s abajo 2 Funcionamiento 2 1 Ajuste de la hora Para ajustar la fecha y hora actuales pulse el bot n Aceptar durante unos 3 segundos el a o establecido actualmente empe...

Page 14: ...erta se abre y cierra cuando se alcanza el nivel de luminosidad establecido Las horas de apertura y cierre del temporizador consulte el apartado E 2 2 permanecen activas cuando se utiliza el sensor de...

Page 15: ...ruida por lo que resulta dif cil moverla por ejemplo debido a suciedad presente en el ra l gu a La puerta debe desplazarse sin dificultad retire la suciedad alinee los ra les gu a utilice un lubricant...

Page 16: ...ositivo III Grado de protecci n de la bater a IPX0 Grado de protecci n del dispositivo IP33 PREVISTO NICAMENTE PARA USO DOM STICO 4 Accesorios y art culos de repuesto N m ref 70560 Corredera de 220 x...

Page 17: ...leggere con attenzione le istruzioni e attenersi alle indicazioni e avvertenze fornite Conservare le istruzioni per l uso per ogni utilizzo successivo 2 Utilizzo conforme La porta scorrevole stata mes...

Page 18: ...Premier 1 Supplies 2031 300th St Washington IA 52353 Premier1Supplies com 800 282 6631...

Reviews: