Premier Mounts SCM-103 Installation Instructions Manual Download Page 2

Page 2  

 

 

 

 

 

 

 

 

                    Installation Instructions

Table of Contents

Warning Statements

Warning 

Statements 

         2

Parts 

List 

          3

Installation 

Tools 

         3

Locating 

the 

Mounting 

Points 

        4

Mounting 

the 

Brackets 

to 

the 

Display       5

Securing 

the 

Lower 

Cover 

        6

Securing the Tubes to the Mounting Brackets 

 

 

 

 

 

6

Lifting 

the 

Display 

into 

Position 

       8

Cable 

Routing 

          9

Installing 

the 

Beauty 

Covers 

        12

Technical 

Specifications 

        14

Warranty 

          15

SCM-103

Redundancy in Engineering is the duplication of critical components of a system with the intention of increasing reliability of the system, usually in the 
case of a backup or fail-safe.

IT IS REQUIRED THAT THE INSTALLATION LOCATION BE INSPECTED AND APPROVED BY A 
LICENSED STRUCTURAL ENGINEER.

PRIOR TO THE INSTALLATION OF THIS PRODUCT, THE INSTALLATION INSTRUCTIONS SHOULD BE READ AND COMPLETELY 
UNDERSTOOD. THE INSTALLATION INSTRUCTIONS MUST BE READ TO PREVENT PERSONAL INJURY AND PROPERTY DAMAGE. KEEP 
THESE INSTALLATION INSTRUCTIONS IN AN EASILY ACCESSIBLE LOCATION FOR FUTURE REFERENCE.
PREMIER MOUNTS DOES NOT WARRANT AGAINST DAMAGE CAUSED BY THE USE OF ANY PREMIER MOUNTS PRODUCT FOR 
PURPOSES OTHER THAN THOSE FOR WHICH IT WAS DESIGNED OR DAMAGE CAUSED BY UNAUTHORIZED ATTACHMENTS OR MODIFI-
CATIONS, AND IS NOT RESPONSIBLE FOR ANY DAMAGES, CLAIMS, DEMANDS, SUITS, ACTIONS OR CAUSES OF ACTION OF WHATEVER 
KIND RESULTING FROM, ARISING OUT OF OR IN ANY MANNER RELATING TO ANY SUCH USE, ATTACHMENTS OR MODIFICATIONS.

THE SURFACE MUST BE CAPABLE OF SUPPORTING AT LEAST FIVE TIMES THE WEIGHT OF THE DISPLAY. IF NOT, THE CEILING 
STRUCTURE MUST BE REINFORCED. THE MAXIMUM WEIGHT THAT CAN BE USED WITH THIS PRODUCT IS 2000LBS. PROPER 
INSTALLATION PROCEDURE BY A QUALIFIED SERVICE TECHNICIAN, AS OUTLINED IN THE INSTALLATION INSTRUCTIONS, MUST BE 
ADHERED TO. FAILURE TO DO SO COULD RESULT IN SERIOUS PERSONAL INJURY, OR EVEN DEATH.

SAFETY MEASURES MUST BE PRACTICED AT ALL TIMES DURING THE ASSEMBLY OF THIS PRODUCT. USE PROPER SAFETY GEAR 
AND TOOLS FOR THE ASSEMBLY PROCEDURE TO PREVENT PERSONAL INJURY.

At least two qualified people should perform the assembly procedure. Injury and/or damage can result from dropping or mishandling the display.

If mounting to studs, make sure that the mounting screws are anchored into the center of the studs. Use of an edge-to-edge stud finder is recommended.

This product is intended for indoor use only. Use of this product outdoors could lead to product failure and personal injury.

Do not install near sources of high heat. Do not install on a structure that is prone to vibration, movement or chance of impact

Contact Premier Mounts with any questions 
(800) 368-9700
[email protected]

Summary of Contents for SCM-103

Page 1: ...0 832 4888 EUROPE Swallow House Shilton Industrial Estate Shilton Coventry England CV79JY Phone 44 0 2476 614700 Fax 44 0 2476 614710 AUSTRALIA NEW ZEALAND OCEANIA DISTRIBUTOR P O Box 295 Mordialloc Victoria 3195 Australia Phone 039586 6330 www premiermounts com au Other Locations Phone 001 714 632 7100 Fax 001 714 632 1044 Premier Mounts 2008 9531 027 224 02 ...

Page 2: ...NS AND IS NOT RESPONSIBLE FOR ANY DAMAGES CLAIMS DEMANDS SUITS ACTIONS OR CAUSES OF ACTION OF WHATEVER KIND RESULTING FROM ARISING OUT OF OR IN ANY MANNER RELATING TO ANY SUCH USE ATTACHMENTS OR MODIFICATIONS THE SURFACE MUST BE CAPABLE OF SUPPORTING AT LEAST FIVE TIMES THE WEIGHT OF THE DISPLAY IF NOT THE CEILING STRUCTURE MUST BE REINFORCED THE MAXIMUM WEIGHT THAT CAN BE USED WITH THIS PRODUCT I...

Page 3: ...Premier Mounts 800 368 9700 Recommended Installation Tools Mounting Bracket Covers Qty 2 Mounting Brackets Qty 2 Display Input Cover Qty 1 Tubing Qty 3 Lower Cover Panel Qty 1 Lower Cover Qty 1 Plastic Coupler Inserts Qty 4 8 32 x 3 8 Phillips Screws Qty 18 8 32 x 1 2 Phillips Screws Qty 6 10 32 Kep Nut Qty 4 6 32 x 1 4 Set Screw Qty 4 Clevis Pins Qty 6 SCM 103 Spirit Level Supplied 1 2 Socket and...

Page 4: ...ews with quick release sleeves that are pre installed on the display Mounting Points Mounting Points Step 1 Locate the 4 quick release sleeves on the back of the display and remove Place the M16 bolts and split washers to the side These will be used for bracket installation on the next page SCM 103 ...

Page 5: ...he M16 mounting bolt through the mounting bracket then through the split washer into the display Step 4 Tighten the bolt into place and repeat the steps for the remaining three bolts The following steps will require a minimum of 3 people This should not be done with less then 3 people due to the weight of mounting brackets Right Mounting Bracket Left Mounting Bracket Split Washer M16 Bolt DO NOT O...

Page 6: ...PERFORM ALL INSTALLATION STEPS 8 32 x Screw 10 32 Kep Nut Securing Tubes to Mounting Brackets Step 1 Slide the tubes into the cut outs on the side of the mounting brackets Step 2 Slide the tubes in enough to have an even amount showing on each side of the left right mounting brackets Step 3 Once tubes are slid into place tighten all twelve 12 pre installed set screws located in the display mountin...

Page 7: ...is attached to the display double check all mounting locations to insure all hardware is properly tightened and secured Step 5 Once the tubes are locked into place insert the clevis pins into the hole at the end of each tube Step 6 Lock each clevis pin into place by inserting the attached cotter pin into the hole Cotter Pin 2 Tube Clevis Pin SCM 103 ...

Page 8: ...le Scissor Lift Display Sucured to Pallet Fork Lift SCM 103 The display may be hung from a ceiling structure using two 2 main support cables and two 2 safety cables Length mounting location and method of attachment will be provided by the installer The components below that are used to hang the SCM 103 are sold separately and may be ordered through Premier Mounts 800 368 9700 1 4 stainless steel 7...

Page 9: ... routed so each cable runs through its own hole The system is designed to allow for 2 cables on each mounting bracket 1 cable for support 1 as a safety redundancy cable Step 1 Route the pre hung cables through the top of the left and right mounting brackets attached to the display Step 2 Locate the plastic insert plugs and slip around cable through the cut out in the side of the insert Plastic Ins...

Page 10: ...ert plug down cabling and insert into the top of the mounting bracket A cut out in the mounting bracket is provided that will allow the plastic cap to sit flush with the top of the mounting bracket Step 4 Locate the 6 32 x 1 4 Set Screw and insert into the sides of the plastic top locking the plastic plug into position The set screw location is on the side of each plastic top Tighten the set screw...

Page 11: ...o the cable and thread one 20 nut into position Leveling adjustment can be made at this stage by setting the nut position at different heights on the threaded post attached to the cable Step 8 Slide one flat washer up to the nut and insert the end of the stud into the bottom hole of the mounting bracket Step 9 Locate two 20 nuts one flat washer Step 10 Tighten the two nuts until cable is locked ti...

Page 12: ... locate the display input cover panel Step 2 Install the panel by sliding it into position behind the tubes Step 3 Lock the cover into position by tightening the six 6 8 3 x 3 8 screws Installing the Beauty Covers 8 32 x 3 8 Screw Step 4 Slide the mounting bracket covers into position Mounting Bracket Cover SCM 103 ...

Page 13: ... using the 8 32 x 3 8 screws 8 32 x 3 8 Screws Step 6 Drop the lower cover into position between the 2 display mounting brackets and lock into place using the 8 32 x 3 8 screws provided Step 7 Make sure that the display is level and slowly lower your support equipment Lower Cover SCM 103 ...

Page 14: ...Page 14 Installation Instructions Technical Specifications All measurements are in inches mm SCM 103 ...

Page 15: ... FITNESS FOR A PARTICULAR PURPOSE PREMIER MOUNTS IS NOT RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUD ING BUT NOT LIMITED TO INABILITY TO USE ITS PRODUCTS OR LABOR COSTS FOR REMOV ING AND REPLACING DEFECTIVE PRODUCTS OR PARTS SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU What Custom...

Reviews: