background image

TECHNICAL SPECIFICATION 

Product Code 

EH1910 

Cooling Capacity (Btu/h) 

12,000 

Power Supply 

230V~ 

Rated Cooling Input (W) 

1337 

Rated Current Cooling (A) 

5.9 

EER For Cooling (W/W) 

2.63 

Noise Level (dB) (High) 

65 

Product Dimensions (mm) 

762 x 470 x 353 

Packaging Dimensions (mm) 

878 x 462 x 505 

Refrigerant (Type/Charge) 

R290/240g 

Net Weight (kg) 

29.5 

Gross Weight (kg) 

33 

Application Area (m

2

16-22 

Fan Speeds 

Louvres 

Automatic 

 
 
 
 
 
 
 
 
 
 
 
Prem-i-Air guarantees the product free from defects in materials and workmanship for a period of twelve months. 
Should this appliance be operated under conditions other than those recommended, at voltages other than the 
voltage indicated on the appliance, or any attempts made to service or modify the appliance, then the warranty will 
be rendered void. The product you buy may sometimes differ slightly from illustrations. This warranty is in addition 
to, and does not affect, your statutory rights. Our guarantee is administered by our retailers.  
 
If your product arrives damaged, you must contact the retailer from whom you bought it. The retailer’s contact 
details will be on the invoice that arrived with the product, or on the e-mail you received when you placed the order. 
Do not contact Prem-i-air, only your retailer can arrange a replacement. If your product fails within the guarantee 
period, firstly read the “fault finding” section of this manual, because temperature and weather conditions can affect 
the performance of certain products.  
 
If the product needs to be repaired or replaced, you must contact the retailer from whom you bought it. The 
retailer’s contact details will be on the invoice that arrived with the product, or on the e-mail you received when you 
placed the order. If you have just received your product and require technical help in using it, please call our Help 
Desk on (0845) 459 4816. If you have any other technical queries about the product, please call our Help Desk on 
(0845) 459 4816. 

Prem-i-Air Appliances Ltd., 

Lancots Lane, Sutton, 

St. Helens, Merseyside. 

WA9 3EX 

www.prem-i-air.com 

Summary of Contents for EH1910

Page 1: ...EH1910 12 000BTU Mobile Portable Local Air Conditioner with Remote Control Timer and Wi Fi Please Retain for Future Reference Caution Risk of fire R290 ...

Page 2: ...aterials Do not place the mains lead beneath a carpet or rug Do not use this appliance in locations where paint petrol or other flammable liquids are used or stored Please ensure the appliance is switched off and unplug when not in use Do not use the appliance for other than its intended use Do no insert any object into the appliance through the grilles This may damage the product or result in ove...

Page 3: ...r reference please see the real product for detailed information warning This unit uses a flammable refrigerant If refrigerant leaks and comes in contact with fire or heating part there is risk of fire Read the USER MANUAL carefully before operation Further information is available in the USER MANUAL SERVICE MANUAL and the like Service personnel are required to carefully read the USER MANUAL and S...

Page 4: ... THE EXHAUST HOSE 1 Connect the hose connector to one end of the exhaust hose 2 Connect the windows adaptor kit to the other end of the exhaust hose Exhaust Hose Hose Connector Window Kit Adaptor Remote Control Window Kit ...

Page 5: ... window to secure the kit in place It needs to hold the window kit firmly in place 5 Attach the hose connector to the exhaust air outlet of the unit 6 Adjusting the length of the flexible exhaust hose and avoiding bends in the hose then place the AC in the desired location ...

Page 6: ...perature 16 32 or timer setting 5 Swing Adjust the horizontal air flow direction 6 Timer Sets a time for the unit to automatically start or stop 7 Fan Speed Press to switch the fan speed between High Low and Medium 8 Indicators LED for fan speed High Medium Low and Wi Fi 9 Digital Display Displays timer setting and room temperature 10 Minus Decreasing the desired temperature or timer setting 11 Sl...

Page 7: ...n 16 C and 32 C 2 3 Press SPEED button to adjust the fan speed 2 4 To control the direction of the air flow Press the SWING button Note The air conditioner stops if the room temperature is equal to the selected temperature 3 Ventilating your room 3 1 Press MODE button until the FAN LED is illuminated 3 2 Press SPEED button to adjust the fan speed Note in ventilation mode the room air is circulated...

Page 8: ... 2 Press and hold the TIMER button for about 3 seconds the Wi Fi LED will flash rapidly 3 Launch the app and select 4 Select Air conditioner menu and follow the instructions on the app 5 Once the appliance has been successfully connected the Wi Fi LED will be permanently illuminated 6 To disconnect press and hold the TIMER button for about 3 seconds the appliance will disconnect and the Wi Fi LED ...

Page 9: ... to empty the drainage tank in cooling operation except in exceptionally high humidity conditions The condensate water evaporates at the condenser and is evacuated through the exhaust hose For continuous operation un drying mode please connect the attached drain hose to the unit Condensate water can then be directly drained into a bucket or similar Switch off the unit before this operation Remove ...

Page 10: ...gh the filter in the opposite direction of air flow Set aside and allow the filter to air dry before reinstalling WARNING To prevent accidental injury from extreme temperatures and sharp edges do not touch the evaporator surface STORAGE For long term storage more than a few weeks it is best to clean the unit and dry it out completely 1 Unplug the unit and remove exhaust hose and window kit 2 Drain...

Page 11: ...ust hose is detached Make sure the exhaust hose is securely attached Water Leakage Overflow while moving the unit Empty the water tank before transport Check if the drain hose is kinked or bends Straighten the hose to avoid a trap existing Excessive Noise Check if the unit is securely positioned Place the unit on horizontal and firm ground Check if any loose vibrating parts Secure and tight the pa...

Page 12: ...ect the brown wire to the terminal labelled L Connect the blue wire to the terminal labelled N Connect the green and yellow wire to the upper terminal labelled E Make sure that the cord grip is positioned correctly over the outer sheath of the cable and it fully tightened If the plug is fitted with a fuse other than 13A then please replace with an approved fuse of the correct value OPERATING COSTS...

Page 13: ...Our guarantee is administered by our retailers If your product arrives damaged you must contact the retailer from whom you bought it The retailer s contact details will be on the invoice that arrived with the product or on the e mail you received when you placed the order Do not contact Prem i air only your retailer can arrange a replacement If your product fails within the guarantee period firstl...

Reviews: