Preferred Instruments - Feedwater Center 

10

Modbus 

Coil 

Address

Read/

Write 

Allowed

 

coil = 0

  

coil = 1

00001
00002
00003 ST Level Control Valve Auto/Manual

Y

Auto

Manual

00004
00005
00006
00007
00008 Transfer Pump Quantity Auto/Manual

Y

Auto

Manual

00009 Transfer Pump Lead Select Auto/Manual 

Y

Rotate

Manual

00010 Transfer Pump Fault Reset

Y

Reset

Normal

00011 Remote Alarm Silence

Y

Reset

Normal

00012
00013
00014
00015
00016
00017
00018 Has Makeup Water Flow

Y

NOT USED INSTAL’D

00019 Has Makeup Water Pressure

Y

NOT USED INSTAL’D

00020 Has Condensate Return Temperature

Y

NOT USED INSTAL’D

00021 Has Condensate Return Flow

Y

NOT USED INSTAL’D

00022 Has Surge Tank Installed

Y

Valve

PUMP

00023
00024
00025
00026
00027 Transfer Pump Always On

Y

NO

YES

00028
00029 Sychronize Time

Y

FALSE

TRUE

00030 Has Surge Tank Level

Y

NOT USED INSTAL’D

00031
00032
00033 spare
00034 spare
00035 spare
00036 spare
00037 spare
00038 spare
00039 spare
00040 Common Alarm

Alarm

Normal

00041
00042
00043
00044

MODBUS ADDRESSING

Note: Modbus address “00xxx” means Holding Register xxx

Summary of Contents for JC-FWC-ND

Page 1: ...Preferred Instruments Danbury CT USA http www PreferredInstruments com Feedwater Center Model JC FWC ND OIT JC FWC ND Quick Start Guide...

Page 2: ...evision 0 0 02 13 2019 INTRODUCTION This guide is designed to simplify the commissioning process by detailing the initial parameters required to properly setup a Preferred Instruments Feedwater Cen te...

Page 3: ...n the NOT USED to INSTAL D NOT USED MAKE UP PRESSURE If the system being set up has a Pressure sensor on the Make Up water line going into the Surge tank turn the NOT USED to INSTAL D NOT USED SURGE T...

Page 4: ...ge NOT USED to INSTAL D This enables the Level Control Valve output PARAMETER SETUP 2 deals with the scope and type of control being used A description of the effect of each pa rameter are provided PA...

Page 5: ...t Editor please reference the Operation and Installation manual SDI JC FWC ND OIT ID NAME VALUE 0 VALUE100 DECPT HELP COMMENTS A1 A2 ST LVL 0 0 1000 1 Surge Tank Level in WC A3 A4 STF 50 300 0 Surge T...

Page 6: ...anual SDI JC FWC ND OIT MODBUS The following information applies to JC FWC ND OIT Feedwater Center Transfer Pump Surge Tank Control Default Options Device Address 1 1 31 Baud 19200 1200 2400 4800 9600...

Page 7: ...40021 Surge Tank Low Low Level Alarm Delay Y 100 0 secs 40022 40023 40024 40025 40026 40027 40028 40029 40030 40031 40032 40033 40034 40035 40036 Surge Tank Level for 100 MU Valve Y 100 0 40037 Surge...

Page 8: ...dd l Start Lag Delay Y 0 100 secs 40059 Transfer Pump Add l Stop Lag Delay Y 0 100 secs 40060 Transfer Pump Quantity Y 0 100 secs 40061 Transfer Pump Rotate Runtime Hours Y 0 100 40062 Transfer Pump 1...

Page 9: ...0 GPM 40095 Surge Tank Pump 1 Elapsed Time 0 10000 Hrs 2 40096 Surge Tank Pump 2 Elapsed Time 0 10000 Hrs 2 40097 Surge Tank Pump 3 Elapsed Time 0 10000 Hrs 2 40098 40099 40100 40101 40102 40103 40104...

Page 10: ...018 Has Makeup Water Flow Y NOT USED INSTAL D 00019 Has Makeup Water Pressure Y NOT USED INSTAL D 00020 Has Condensate Return Temperature Y NOT USED INSTAL D 00021 Has Condensate Return Flow Y NOT USE...

Page 11: ...061 Surge Tank Low Level Alarm Alarm Normal 00062 Surge Tank Low Low Level Alarm Alarm Normal 00063 Surge Tank High Level Alarm Alarm Normal 00064 00065 00066 00067 00068 00069 Transfer Pump 1 Active...

Page 12: ...99 00100 00101 Surge Tank MU Valve in Auto Auto On or Off 00102 00103 Spare Yes No 00104 Spare Yes No 00105 Transfer Pump 1 Speed in Auto Auto On or Off 00106 Transfer Pump 2 Speed in Auto Auto On or...

Page 13: ...2 627 DIN 1 DI 1 13 628 DIN 1 DI 1 14 629 DIN 1 DI 1 15 Disable All BAS Contact 630 HOA ROUT 2 HO 2 1 Transfer Pump 1 Start Circuit 631 HOA ROUT 2 HO 2 2 Transfer Pump 2 Start Circuit 632 HOA ROUT 2 H...

Page 14: ...677 A M AOUT 5 AM 5 3 Transfer Pump 3 Speed 678 A M AOUT 5 AM 5 4 Transfer Pump 4 Speed 679 A M AOUT 5 AM 5 5 Transfer Make Up Water Valve 690 AIN 6 AI 6 1 Make Up Water Flow 691 AIN 6 AI 6 2 Make Up...

Page 15: ...15 Preferred Instruments Feedwater Center Model JC FWC ND OIT NOTES...

Page 16: ...Preferred Instruments Feedwater Center Model JC FWC ND OIT 16 REVISION HISTORY REV 0 0 FIRST ISSUE 02 13 2019 Description SDI FWC ND OIT QS Revision 0 0 02 13 2019...

Page 17: ...A Division of Preferred Utilities Manufacturing Corp 31 35 South St Danbury CT 06810 www Preferred MFG com Phone 203 743 6741 Email info preferred mfg com...

Reviews: