C100i Adaptive Motion Trainer
Page 9
13. Press the
OK
key,
PWRB
will be displayed with the current power bit reading. Pressing
the resistance
S
,
T
will change the power bit setting.
14. Press the
CLEAR
key then the
T
key,
RPM TEST
will scroll across the display.
15. Press the
OK
key,
RPM
will be displayed.
16. Press the
OK
key,
PULSE
will be displayed with the current speed pulse count.
17. Press the
CLEAR
key then the
T
key,
BATTERY TEST
will scroll across the display.
18. Press the
OK
key,
the current battery voltage will be displayed.
19. Press the
CLEAR
key then the
T
key,
STRIDE POSITION TEST
will scroll across the
display.
20. Press the
OK
key,
the low, high and actual stride positions will be displayed. The low
display shows the lowest position reading achieved during the test. The high display
shows the highest position reading achieved during the test. The actual display
changes with the current stride position. Stride on the AMT to the maximum horizontal
movement in both directions. At maximum stride length the low stride display should
read 0 and the high stride display should read 40.
21. Press the
OK
key,
the low and stride positions will be displayed.
22. Press the
RESET