C100i Adaptive Motion Trainer
Page 19
Procedure 5.1 - Measuring the Resistance of a Generator
Caution
If a external power supply is connected to the C100i, disconnect the external power supply from
the C100i before continuing with this procedure.
Procedure
1.
Remove the right side cover per Procedure 7.12.
2.
Remove the red battery wire from the lower PCA. See Diagram 5.1.
WARNING
Before continuing with this procedure, review the Warning and Caution statements listed in
Section One, Things You Should Know.
3.
Set the ohmmeter to a range that will conveniently read up to 50
:
.
4.
Remove the two wires from the
LOAD
terminals of the lower PCA.
5.
With an ohmmeter, read between the wires removed in step 5. The reading should be
approximately 10
:
Replace the two wires removed in step 5.
6.
Remove the three wires from the
3 PHASE GEN IN
terminals of the lower PCA.
7.
With an ohmmeter, read between the red & white, red & black and white & black wires.
Each reading should be approximately 25
:
Reconnect the wires removed in step 7
8.
If any of the readings are significantly high or significantly low, remove the intermediate
cable from the generator and perform the same measurements as in step 4 on the
generator connector. If the reading are now correct check and or replace the
intermediate cable.refer to Diagram 5.1. If the readings are still incorrect, remove the
three phase generator.
9.
Reconnect the red battery wire removed in step 3.
10. Replace the right side cover.