Removing and Replacing the Upper PCA
7.
Carefully disconnect the keyboard cable from the upper PCA. See Diagram 6.1.
8.
Disconnect the cables from the matrix PCA and the and the D-pad PCA. See Diagram
7.1.
9.
Unsnap the upper PCA from the display housing front panel.
Note:
Package the upper PCA in an anti-static bag and document the problem as described in
Procedure 3.6, Documenting Software Problems.
10. Position the upper PCA at its mounting location on the display housing front panel and
snap it into place (refer to Diagram 6.1).
11. Reconnect the keyboard cable, D-pad cable and matrix PCA cable to the upper PCA.
See Diagram 6.1
12. Starting from the bottom and working upward, snap the display front panel onto the
display housing.
13. Reconnect the interconnect and heart rate cables to the upper PCA.
14. Remove the ground wire of the wrist strap from the C100i frame, then remove the wrist
strap from your arm.
15. Position the display’s rear cover on the display housing. Replace and tighten the
display mounting screws.
16. Replace the red battery wire removed in step 1 and check unit operation as described
in Section Four.