C776i Stairclimber
Page 54
6.
Remove the four bolts that fasten the generator to the frame. See Diagram 7.15.
Diagram 7.15 - Generator Mounting
7.
Remove the generator belt from the generator then remove the generator from the climber.
8.
Set the replacement generator at its mounting position. Hand start, but do not tighten the
four generator mounting bolts removed in step 6. Set the generator belt on the generator’s
pulley.
9.
Place the belt tension gauge on the generator belt as shown in Diagram 5.3.
10. Using the slots in the frame and a flat metal bar as a lever, move the generator until the belt
tension is 80 pounds and torque the four generator mounting bolts to 40 inch pounds.
11. Set the lower printed circuit assembly mounting plate at its mounting position on the
generator and fasten it with the screws removed in step 5.
12. Set the lower printed circuit assembly in its mounting position on its mounting plate and
fasten it with the screws removed in step 4.
13. Connect the red lead from the battery to the
B
terminal. Connect the black lead
from the battery to
BATTERY -
terminal. See Diagram 7.2.
14. Connect the two red wires from the generator to the
LOAD
terminals. These wires may be
connected in any order.
15. Connect the red, black and white wires from the generator to the
3 PHASE GEN IN
terminals. These wires may be connected in any order.
16. Connect the data cable to its connector on the lower printed circuit assembly.
Mounting
Bolt