Procedure 7.15 - Replacing a Stairarm Foot Plate
1.
Remove the left hand or right hand cover, as required, per Procedure 7.1.
2.
Grasp the stairarm return spring and carefully remove it from its mounting peg. See Diagram
5.1.
1.
Support the stairarm and remove the stairarm belt from both flanged pulleys and the HTD
pulley. Lower the stairarm to its lowest position.
2.
Remove the four set screws that retain the foot plate shafts. See Diagram 7.11.
Diagram 7.11 - Stairarm Foot Plate Mounting
3.
While supporting the foot plate, remove both foot plate shafts and remove the foot plate.
4.
Remove the bolts that retain the belt clamp and remove the belt from the foot plate.
5.
Set the replacement foot plate in its mounting position and replace both the long and short
foot plate shaft as shown in Diagram 7.11.
6.
Verify that the ends of the foot plate shafts are flush with the edge of the foot plates. Apply
blue loctite to the set screws, removed in step 2, and secure the foot plate shafts with the set
screws.
7.
Feed the belt into the stairarm foot plate through the slot in the front edge of the stairarm
foot plate. Replace the clamp and fasten the belt in the clamp with the bolts removed in step
4.
Stairarm
Foot Plate
Set Screws
Set Screws
Stairarm
Belt Clamp
Long Foot
Short Foot
Plate Shaft