Procedure 7.19 - Replacing a Display Column
1.
Remove the left hand, right hand and rear covers per Procedure 7.1.
2.
Remove the left and right handlebars per Procedure 7.14, steps 1-5.
3.
Remove the vertical handlebar per Procedure 7.13, steps 1-3. Remove the handlebar
clamp.
4.
Remove the rear display cover screw and the rear display cover. See Diagram 6.1.
5.
Disconnect the upper data cable from the mid-point connector. See Diagram 7.17.
Diagram 7.17 - Upper Data Cable
6.
Remove the four screws that fasten the display housing to the display column. See Diagram
7.18. Carefully, remove the display housing from the display column while extracting the
data cable and heart rate cable from the display column.
7.
Remove the two front cover bracket screws. See Diagram 7.19. Remove the two lower
column mounting bolts and remove the front cover bracket from the climber.
8.
While supporting the display column, remove the two upper display column mounting bolts.
Remove the display column from the climber.
9.
Slide the top cover and grommet off of the display column.
10. Slide the grommet (with rounded edge upward) and the top cover onto the replacement
display column.
Upper Data
Cable
Mid-Point
Connector
Display
Column