![Precor C546 Service Manual Download Page 80](http://html1.mh-extra.com/html/precor/c546/c546_service-manual_1594685080.webp)
C546 Elliptical Fitness Crosstrainer
Page 80
Procedure 7.13 - Replacing a Pillow Block Bearing
1.
Current production of C546’s utilize an assembly that consists of the eddy current disk, input
pulley assembly and pillow block bearings. The pillow block bearings are permanently
attached to the input pulley shaft and can not be removed. If you encounter a situation
where a pillow block bearing is damaged and requires replacement, the entire assembly
consisting of eddy current disk, input pulley and pillow block bearings must be replaced. See
Procedure 7.17 for replacement instructions.
2.
The pillow block bearings contains grease fitting. It is recommended that the bearings be
periodically checked and greased if necessary.
Diagram 7.14 - Pillow Block Bearings
Mounting Nut
Pillow Block
Bearing
Grease Fitting
Eddy Current
Disk Assembly
Input Pulley
Summary of Contents for C546
Page 55: ...C546 Elliptical Fitness Crosstrainerl Page 55 section to the front cover section ...
Page 111: ...C546 Elliptical Fitness Crosstrainerl Page 111 Wiring Diagram 8 1 C546 120 Vac version 1 ...
Page 112: ...C546 Elliptical Fitness Crosstrainer Page 112 Block Diagram 8 2 C546 120 Vac version 1 ...
Page 114: ...C546 Elliptical Fitness Crosstrainer Page 114 Block Diagram 8 4 C546 240 Vac version 1 ...
Page 116: ...C546 Elliptical Fitness Crosstrainer Page 116 Block Diagram 8 6 C546 120 Vac version 2 3 ...
Page 118: ...C546 Elliptical Fitness Crosstrainer Page 118 Block Diagram 8 8 C546 240 Vac version 2 3 ...