9.
Set the on/off switch in the “off” position. Do not exit the diagnostic program in the normal
manner. Exiting the diagnostic program will cause the lift to self center and invalidate the lift
calibration just performed.
10. On version 1, 2 units, raise the ramp assembly to a convenient height and slide the ramp
end cap into the ramp assembly. Hand tighten the four ramp end cap mounting screws and
then torque them to 100 in/lbs.
11. On version 3 units, raise the ramp assembly to a convenient height and slide the lift yoke
into the ramp assembly. Hand tighten the four lift yoke mounting screws and then torque
them to 240 in/lbs.
Diagram 7.12 - Ramp End Cap or Lift Yoke Mounting
12. Set the on/off switch in the “on” position. Thoroughly test all lift related functions per Section
Four.
13. Set the on/off switch in the “off” position, replace the front cover.