C546 Elliptical Fitness Crosstrainerl
Page 107
Procedure 7.29 - Replacing a Power Entry Module
(version 2,3 units manufactured after 10-15-2000)
Procedure
Note:
The power entry module on this EFX is a multifunction unit. It functions as a power entry
module, A.C. line fuse holder, on/off switch and A.C.ine filter.
1.
Set the on/off switch in the off position. Remove the A.C. line cord from the A.C. outlet and
from the power entry module.
2.
Remove the rear cover per Procedure 7.1.
Diagram 7.27 - Power Entry Module
3.
Remove the blue wire from terminal D and the brown wire from terminal A of the power entry
module.
4.
Remove the two screws that mount the power entry module to the rear cover support.
5.
Open the fuse compartment and remove both fuses (See Procedure 7.30). Check both
fuses with an ohmmeter. They should read approximately 1
Ω
or less. Replace any fuse that
reads significantly high.
6.
Install the tested fuses, from step 5, in the replacement power entry module.
Blue Wire
Brown Wire
Green Wire
Fuse
Access Door
On/Off
Switch
A.C. Input
Summary of Contents for C546
Page 55: ...C546 Elliptical Fitness Crosstrainerl Page 55 section to the front cover section ...
Page 111: ...C546 Elliptical Fitness Crosstrainerl Page 111 Wiring Diagram 8 1 C546 120 Vac version 1 ...
Page 112: ...C546 Elliptical Fitness Crosstrainer Page 112 Block Diagram 8 2 C546 120 Vac version 1 ...
Page 114: ...C546 Elliptical Fitness Crosstrainer Page 114 Block Diagram 8 4 C546 240 Vac version 1 ...
Page 116: ...C546 Elliptical Fitness Crosstrainer Page 116 Block Diagram 8 6 C546 120 Vac version 2 3 ...
Page 118: ...C546 Elliptical Fitness Crosstrainer Page 118 Block Diagram 8 8 C546 240 Vac version 2 3 ...